Use of a power injector during dynamic computed tomography.

W P Shuman, J L Adam, S A Schoenecker, P R Tazioli, A A Moss.   

Abstract

We instituted the use of a power injector during dynamic body CT to improve control of the rate of contrast injection, to make it unnecessary for a technologist to remain in the gantry room during scanning, and to make it possible for one technologist to simultaneously perform the injection and operate the scanner. We analyzed the first 240 cases using the power injector for quality of contrast enhancement and frequency of complications, including contrast material extravasation into soft tissues. Ninety-seven percent of the studies had enhancement judged good, very good, or excellent. A technologist remained in the gantry room during some portion of the examination in only 11% of the studies. Minor contrast material extravasation occurred in two cases and major extravasation in one case, a frequency of 1.3%. None of these resulted in long-term morbidity.

Mesh:

Substances:

Year:  1986        PMID: 3782538     DOI: 10.1097/00004728-198611000-00020

Source DB:  PubMed          Journal:  J Comput Assist Tomogr        ISSN: 0363-8715            Impact factor:   1.826


  6 in total

1.  Hepatic spiral CT in children: scan delay time-enhancement analysis.

Authors:  G D Luker; M J Siegel; D A Bradley; J D Baty
Journal:  Pediatr Radiol       Date:  1996

2.  Detection of liver neoplasms: techniques and outcomes.

Authors:  R L Baron
Journal:  Abdom Imaging       Date:  1994 Jul-Aug

3.  Evaluation of the acute adverse reaction of contrast medium with high and moderate iodine concentration in patients undergoing computed tomography.

Authors:  Masashi Nagamoto; Tatsuya Gomi; Hitoshi Terada; Shigehiko Terada; Eiichi Kohda
Journal:  Radiat Med       Date:  2006-12-25

4.  Safe use of power injectors with central and peripheral venous access devices for pediatric CT.

Authors:  S C Kaste; C W Young
Journal:  Pediatr Radiol       Date:  1996

5.  Contrast media extravasations in patients undergoing computerized tomography scanning: a systematic review and meta-analysis of risk factors and interventions.

Authors:  Sandrine Ding; Nicole Richli Meystre; Cosmin Campeanu; Giuseppe Gullo
Journal:  JBI Database System Rev Implement Rep       Date:  2018-01

6.  The effect of four-phasic versus three-phasic contrast media injection protocols on extravasation rate in coronary CT angiography: a randomized controlled trial.

Authors:  Júlia Karády; Alexisz Panajotu; Márton Kolossváry; Bálint Szilveszter; Ádám L Jermendy; Andrea Bartykowszki; Mihály Károlyi; Csilla Celeng; Béla Merkely; Pál Maurovich-Horvat
Journal:  Eur Radiol       Date:  2017-05-24       Impact factor: 5.315

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.