Literature DB >> 3782002

Validity/reliability of sweat analysis by whole-body washdown vs. regional collections.

P W Lemon, K E Yarasheski, D G Dolny.   

Abstract

Six subjects (25.3 +/- 3.3 yr, mean +/- SD) exercised for 60 min at 42 +/- 4 [low (L)], 55 +/- 6 [moderate (M)], and 67 +/- 4 %VO2max [high (H)] in a moderate environment. Sweat collected from upper back (UB), lower back (LB), midchest (MC), stomach (S), and thigh (T) areas as well as by whole-body washdown (W) was analyzed for urea nitrogen (N). With the exception of the L where all regional measures were similar, all sites overestimated W (several significantly, P less than 0.05). Regression analysis estimations of W (mg/h) from regional collections were as follows--L: W = 0.727 (S) - 1.366(UB) + 1.181(T) + 65.470 +/- 29.5, R = 0.90; M: W = 0.598(MC) - 0.649(UB) + 0.244(LB) + 43.238 +/- 30.4, R = 0.99; H: W = 0.274(S) - 0.560(T) + 0.223(MC) + 131.104 +/- 4.3, R = 0.99; All Intensities: W = 0.497(MC) - 0.483(T) + 0.112(LB) + 69.554 +/- 31.5, R = 0.96. W recovery of exogenous urea N applied to each subject's body was 98.3 +/- 2.7% (mean +/- SE). Interinvestigator reliability coefficient (r = 0.511) was significant (P less than 0.01) but relatively low and the between investigator urea N recovery (93.3 +/- 3.7 vs. 103.2 +/- 3.5%) was significantly different (P less than 0.05). Repeated W determinations by the same investigator were not different (P greater than 0.05), but intrainvestigator reliability coefficients differed widely (0.385 vs. 0.820). Together, these data indicate that W solute recovery can be high; however, both inter- and intrainvestigator reliability can vary.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3782002     DOI: 10.1152/jappl.1986.61.5.1967

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  9 in total

1.  Low abundance of sweat duct Cl- channel CFTR in both healthy and cystic fibrosis athletes with exceptionally salty sweat during exercise.

Authors:  Mary Beth Brown; Karla K V Haack; Brian P Pollack; Mindy Millard-Stafford; Nael A McCarty
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2011-01-12       Impact factor: 3.619

2.  A modified, local sweat collector for warm and humid conditions.

Authors:  P Boisvert; K Nakamura; S Shimai; G R Brisson; M Tanaka
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1993

3.  Exercise-induced sweat nitrogen excretion: evaluation of a regional collection method using gauze pads.

Authors:  P Colombani; S Späti; C Spleiss; P Frey-Rindova; C Wenk
Journal:  Z Ernahrungswiss       Date:  1997-09

Review 4.  Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

Authors:  Lindsay B Baker
Journal:  Sports Med       Date:  2017-03       Impact factor: 11.136

Review 5.  Physiology of sweat gland function: The roles of sweating and sweat composition in human health.

Authors:  Lindsay B Baker
Journal:  Temperature (Austin)       Date:  2019-07-17

Review 6.  Physiological mechanisms determining eccrine sweat composition.

Authors:  Lindsay B Baker; Anthony S Wolfe
Journal:  Eur J Appl Physiol       Date:  2020-03-02       Impact factor: 3.078

7.  Skin-interfaced microfluidic system with personalized sweating rate and sweat chloride analytics for sports science applications.

Authors:  Lindsay B Baker; Jeffrey B Model; Kelly A Barnes; Melissa L Anderson; Stephen P Lee; Khalil A Lee; Shyretha D Brown; Adam J Reimel; Timothy J Roberts; Ryan P Nuccio; Justina L Bonsignore; Corey T Ungaro; James M Carter; Weihua Li; Melissa S Seib; Jonathan T Reeder; Alexander J Aranyosi; John A Rogers; Roozbeh Ghaffari
Journal:  Sci Adv       Date:  2020-12-11       Impact factor: 14.136

8.  Aerobic fitness does not modulate protein metabolism in response to increased exercise: a controlled trial.

Authors:  Tracey J Smith; Matthew A Pikosky; Ann Grediagin; Carmen Castaneda-Sceppa; Lauri O Byerley; Ellen L Glickman; Andrew J Young
Journal:  Nutr Metab (Lond)       Date:  2009-06-16       Impact factor: 4.169

9.  The proteomic and metabolomic characterization of exercise-induced sweat for human performance monitoring: A pilot investigation.

Authors:  Sean W Harshman; Rhonda L Pitsch; Zachary K Smith; Maegan L O'Connor; Brian A Geier; Anthony V Qualley; Nicole M Schaeublin; Molly V Fischer; Jason J Eckerle; Adam J Strang; Jennifer A Martin
Journal:  PLoS One       Date:  2018-11-01       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.