Literature DB >> 378129

Rapid, single-step most-probable-number method for enumerating fecal coliforms in effluents from sewage treatment plants.

E F Munoz, M P Silverman.   

Abstract

A single-step most-probable-number method for enumerating fecal coliforms in sewage treatment plant effluents is described. The method requires the use of only one lactose-based medium and a single incubation temperature of 44.5 degrees C, and it can be completed in 18 h or less, as compared with up to 72 h for the standard most-probable-number method. The appearance of growth is the sole criterion used for designating positives, which can be determined either by increases in the electrical impedance ratio of inoculated medium, as compared to an uninoculated control using a Bactometer model 32, or by visual examination of inoculated medium for turbidity. In trials with 53 samples of unchlorinated sewage treatment plant effluent, fecal coliform counts by the single-step most-probable-number method, throughout a range of less than 10 to almost 10(7) fecal coliforms per 100 ml of effluent, were in excellent agreement with counts abtained by the standard most-probable-number procedure. Similar agreement was obtained in comparative trials with 31 chlorinated effluent samples from two sewage treatment plants. Overall, 87% of 452 positives were confirmed as containing fecal coliforms. The applicability of the single-step most-probable-number method to automated sewage treatment plant operations is discussed.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 378129      PMCID: PMC243249          DOI: 10.1128/aem.37.3.527-530.1979

Source DB:  PubMed          Journal:  Appl Environ Microbiol        ISSN: 0099-2240            Impact factor:   4.792


  6 in total

1.  Improved membrane filter method for fecal coliform analysis.

Authors:  R E Rose; E E Geldreich; W Litsky
Journal:  Appl Microbiol       Date:  1975-04

2.  Automated electrical impedance technique for rapid enumeration of fecal coliforms in effluents from sewage treatment plants.

Authors:  M P Silverman; E F Munoz
Journal:  Appl Environ Microbiol       Date:  1979-03       Impact factor: 4.792

3.  Membrane filter technique for the quantification of stressed fecal coliforms in the aquatic environment.

Authors:  D G Stuart; G A McFeters; J E Schillinger
Journal:  Appl Environ Microbiol       Date:  1977-07       Impact factor: 4.792

4.  Two-temperature membrane filter method for enumerating fecal coliform bacteria from chlorinated effluents.

Authors:  B L Green; E M Clausen; W Litsky
Journal:  Appl Environ Microbiol       Date:  1977-06       Impact factor: 4.792

5.  Rapid detection of microbial contamination in frozen vegetables by automated impedance measurements.

Authors:  D Hardy; S J Kraeger; S W Dufour; P Cady
Journal:  Appl Environ Microbiol       Date:  1977-07       Impact factor: 4.792

6.  Evaluation of coliform tests for chlorinated secondary effluents.

Authors:  S Lin
Journal:  J Water Pollut Control Fed       Date:  1973-03
  6 in total
  1 in total

1.  Automated electrical impedance technique for rapid enumeration of fecal coliforms in effluents from sewage treatment plants.

Authors:  M P Silverman; E F Munoz
Journal:  Appl Environ Microbiol       Date:  1979-03       Impact factor: 4.792

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.