Literature DB >> 3779917

Color Doppler detection of multiple ventricular septal defects.

A Ludomirsky, J C Huhta, G W Vick, D J Murphy, D A Danford, W R Morrow.   

Abstract

Combined two-dimensional and Doppler echocardiography has a high sensitivity and specificity for detection of isolated perimembranous ventricular septal defects. However, muscular or multiple ventricular septal defects may be difficult to diagnose with noninvasive methods, particularly in older children, necessitating angiography for accurate diagnosis. Detection of single and multiple ventricular septal defects with two-dimensional color flow mapping was compared with detection by standard two-dimensional imaging and Doppler. Both techniques were compared with four-chamber left ventricular angiography. Fifty-one patients (age 3 months to 25 years, mean 5.6 years) were studied. Eighteen had solitary ventricular septal defects, 18 had multiple ventricular septal defects, and 15 patients with intact ventricular septum served as a control group. At least one ventricular septal defect was detected by color Doppler and two-dimensional/Doppler methods in all patients with ventricular septal defect proved by angiography with no false positives. In the detection of multiple ventricular septal defects, the sensitivity of color Doppler was 72% and that of two-dimensional/Doppler was 38% (100% specificity in both). Color Doppler failed to identify multiple ventricular septal defects in five patients (two weighing less than 4 kg and three with reduced pulmonary blood flow). However, no large additional muscular defects were missed by imaging and color Doppler. Color Doppler is useful for the detection of ventricular septal defects and has higher sensitivity than two-dimensional/Doppler for multiple ventricular septal defects. The contribution of color Doppler appears to be in the detection of additional small muscular ventricular septal defects.

Entities:  

Mesh:

Year:  1986        PMID: 3779917     DOI: 10.1161/01.cir.74.6.1317

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  6 in total

1.  Preoperative evaluation and surgery in isolated ventricular septal defects: a 21 year perspective.

Authors:  A Nygren; J Sunnegårdh; H Berggren
Journal:  Heart       Date:  2000-02       Impact factor: 5.994

2.  Sensitivity and speed of colour Doppler flow mapping compared with continuous wave Doppler for the detection of ventricular septal defects.

Authors:  D T Linker; O Rossvoll; J V Chapman; B A Angelsen
Journal:  Br Heart J       Date:  1991-04

3.  Potential value of intraoperative Doppler colour flow mapping in operations for complex intracardiac shunting.

Authors:  G R Sutherland; S Balaji; J L Monro
Journal:  Br Heart J       Date:  1989-12

4.  The natural history of ventricular septal defects.

Authors:  S W Turner; S Hunter; J P Wyllie
Journal:  Arch Dis Child       Date:  1999-11       Impact factor: 3.791

5.  Colour flow imaging in the diagnosis of multiple ventricular septal defects.

Authors:  G R Sutherland; J H Smyllie; B C Ogilvie; B R Keeton
Journal:  Br Heart J       Date:  1989-07

Review 6.  Techniques and results in the management of multiple muscular trabecular ventricular septal defects.

Authors:  Tetsuya Kitagawa; Takashi Kitaichi; Mikio Sugano; Hirotsugu Kurobe
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-06-05
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.