| Literature DB >> 37799 |
M J Stewart, P I Adriaenssens, D R Jarvie, L F Prescott.
Abstract
Methods for the estimation of plasma paracetamol which depend on acid hydrolysis to p-aminophenol without a prior extraction step also measure inactive metabolites which are present in high concentrations. The extent of the overestimate obtained with such methods was determined using 24 samples from patents after paracetamol overdosage. There was a positive error of between 40 and 700% compared with a high-performance liquid chromatography reference method which measured only unchanged paracetamol. These non-specific methods should not be used to determine the need for specific therapy in patients with paracetamol poisoning.Entities:
Mesh:
Substances:
Year: 1979 PMID: 37799 DOI: 10.1177/000456327901600118
Source DB: PubMed Journal: Ann Clin Biochem ISSN: 0004-5632 Impact factor: 2.057