Specific absorption rate (SAR) and tissue temperature were measured for a total of 83 treatments in 33 patients who received local hyperthermia treatment for cancer. The patients were grouped into three categories according to tumor size. Hyperthermia was induced by 13.56 MHz electromagnetic energy applied using capacitive coupling. A method is described for evaluating SAR from the tissue temperature traces at any time in the treatment when a step change is made in applied power. The method is possible only if the temperature traces are free from interference and the total power delivered to the patient is monitored. Mean values of SAR ranged from 4.6 to 89 W kg-1 depending on the treatment site. Satisfactory heating was achieved for superficial tumors, with temperatures greater than 42 degrees C being recorded in 69% of treatments. For axillary nodes only 4% of treatments exceeded 42 degrees C. For cervix tumors an idealized tumor model was used to estimate tumor temperature from the temperature and SAR measured in the adjacent normal tissue. From the model it appears necessary either to raise the systemic temperature to 40 degrees C or to increase the SAR by at least a factor of 4 to obtain a temperature of 42 degrees C in a typical tumor. Measurements of SAR and temperature are essential for feedback control of computer models which, in principle, could provide a complete distribution of temperature during a hyperthermia treatment. Furthermore, measured SAR provides a direct comparison of the power deposition from different treatment machines in a clinical environment. The data presented form a basis for comparison with the clinical use of other heating systems.

Entities:  

Mesh:

Year:  1986        PMID: 3771318     DOI: 10.1016/0360-3016(86)90137-9

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

Review 1.  Heterogeneous Heat Absorption Is Complementary to Radiotherapy.

Authors:  Andras Szasz
Journal:  Cancers (Basel)       Date:  2022-02-11       Impact factor: 6.639

2.  Exhaustion of Protective Heat Shock Response Induces Significant Tumor Damage by Apoptosis after Modulated Electro-Hyperthermia Treatment of Triple Negative Breast Cancer Isografts in Mice.

Authors:  Lea Danics; Csaba András Schvarcz; Pedro Viana; Tamás Vancsik; Tibor Krenács; Zoltán Benyó; Tamás Kaucsár; Péter Hamar
Journal:  Cancers (Basel)       Date:  2020-09-10       Impact factor: 6.639

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.