Literature DB >> 3762915

Development of a new universal neuroangiographic unit.

M Takahashi, M Miyawaki, H Bussaka.   

Abstract

A new neuroangiographic unit has been developed with use of a "C" type gantry, which is capable of rotation and angulation for various angiographic projections. Two sets of a twin focal X-ray tube and an imaging system are mounted on the gantry. Each imaging system consists of a 9 inch image intensifier and a 14 X 14 rapid film changer, which can be exchanged in position rapidly. Stereoscopic magnification and stereoscopic contact angiography, fluoroscopy and DSA are performed in monoplane and biplane and switched over to each other expeditiously and easily. The detailed angiographic information is obtained with lower complication rate and lower exposure to patients. Interventional neuroradiologic procedures are performed efficiently on this unit.

Entities:  

Mesh:

Year:  1986        PMID: 3762915     DOI: 10.1007/bf00333444

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  6 in total

1.  Abdominal, thoracic and peripheral angiography with an angiographic system of high maneuverability.

Authors:  M Takahashi; H Bussaka; M Miyawaki; T Nakanishi
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1986-04-25

2.  Stereoscopic magnification angiography using a twin focal-spot x-ray tube.

Authors:  M Takahashi; Y Ozawa
Journal:  Radiology       Date:  1982-03       Impact factor: 11.105

3.  Magnification factor, position, and true size of an object in stereoscopic magnification radiography.

Authors:  M Takahashi
Journal:  Radiology       Date:  1982-01       Impact factor: 11.105

4.  [New directions in neuroradiology (author's transl)].

Authors:  M Takahashi
Journal:  Nihon Igaku Hoshasen Gakkai Zasshi       Date:  1982-02-25

5.  Focal-spot separation in stereoscopic magnification radiography.

Authors:  M Takahashi; Y Ozawa; H Takemoto
Journal:  Radiology       Date:  1981-07       Impact factor: 11.105

6.  Abdominal angiography with stereoscopic magnification.

Authors:  M Takahashi; Y Ozawa
Journal:  Cardiovasc Intervent Radiol       Date:  1981       Impact factor: 2.740

  6 in total
  2 in total

1.  Development of a ceiling-suspended angiographic unit for interventional neuroradiology.

Authors:  M Takahashi; H Bussaka; Y Yamashita; Y Korogi; K Takechi; K Matsuo
Journal:  Neuroradiology       Date:  1991       Impact factor: 2.804

2.  Neuroradiological applications of a new system of stereoscopic biplane digital subtraction angiography.

Authors:  K Hasuo; A Mizushima; S Matsumoto; F Mihara; T Yoshiura; Y Umezu; K Masuda
Journal:  Neuroradiology       Date:  1996-07       Impact factor: 2.804

  2 in total