Literature DB >> 3760094

Improved determination of sulpiride in plasma by ion-pair liquid chromatography with fluorescence detection.

P Nicolas, F Fauvelle, A Ennachachibi, H Merdjan, O Petitjean.   

Abstract

A specific and sensitive high-performance liquid chromatographic method for the measurement of sulpiride in plasma is described. The internal standard used was veralipride, a structurally related substituted benzamide. A fluorescence detector with maximum excitation at 300 nm and maximum emission at 365 nm was used for quantitation. After an alkaline extraction procedure, the benzamides were separated on a 5-micron ODS column using a large organic counter ion in the mobile phase. The detector response was linear from 10 to 1000 ng/ml and the detection limit was 10 ng/ml, which is sensitive enough for pharmacokinetic studies. The suitability of the method for the analysis of biological samples was tested by studying the variation with time of plasma concentrations of sulpiride in normal human volunteers after a single therapeutic 200-mg oral dose of three different formulations of sulpiride.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3760094     DOI: 10.1016/s0378-4347(00)83605-1

Source DB:  PubMed          Journal:  J Chromatogr


  5 in total

1.  Pharmacokinetics of metoclopramide in patients with liver cirrhosis.

Authors:  E Magueur; H Hagege; P Attali; E Singlas; J P Etienne; A M Taburet
Journal:  Br J Clin Pharmacol       Date:  1991-02       Impact factor: 4.335

2.  The renal effects of atrial natriuretic peptide in man are not attenuated by (+)-sulpiride.

Authors:  S Freestone; T M MacDonald; R F Jeffrey; J Brown; M R Lee
Journal:  Br J Clin Pharmacol       Date:  1989-01       Impact factor: 4.335

3.  (+)-sulpiride antagonises the renal effects of gamma-L-glutamyl-L-dopa in man.

Authors:  T M MacDonald; R F Jeffrey; S Freestone; M R Lee
Journal:  Br J Clin Pharmacol       Date:  1988-02       Impact factor: 4.335

4.  Development of membrane selective electrode for determination of the antipsychotic sulpiride in pharmaceuticals and urine.

Authors:  Ma Soledad García; Joaquín A Ortuño; Ma Isabel Albero; Mustafa Salem Abuherba
Journal:  Sensors (Basel)       Date:  2009-06-03       Impact factor: 3.576

5.  Development and Validation of a UPLC Method by the QbD-Approach for the Estimation of Rabeprazole and Levosulpiride from Capsules.

Authors:  Veera Raghava Raju Thummala; Raja Kumar Seshadri; Satya Sankarsana Jagan Mohan Tharlapu; Mrutyunjaya Rao Ivaturi; Someswara Rao Nittala
Journal:  Sci Pharm       Date:  2014-01-16
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.