Literature DB >> 3758691

Experimental endothelial lesions by means of an ultrasound phacoemulsificator.

H Bleckmann, R Vogt.   

Abstract

The current study deals with experimental use of an ultrasound generator for phacoemulsification and its effect on bovine corneal endothelium. The extent of the endothelial defect was defined by staining cell borders and nuclei. Histological examination showed that endothelial cells on the edge of a defect had no nuclei and were partially detached from the Descemet's membrane in some cases. Quantitative determinations of endothelial cell defects demonstrated the effects of distance from the generator (1, 2, and 3 mm) as well as duration of exposure. At 2 and 3 mm, addition of sodium hyaluronate (Healon) to the incubation medium was associated with a statistically significant reduction in size of the endothelial defect.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3758691     DOI: 10.1007/bf02173363

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  19 in total

1.  The effect of ultrasonic radiation upon the eye and ocular adnexa.

Authors:  G BAUM
Journal:  Am J Ophthalmol       Date:  1956-11       Impact factor: 5.258

2.  The phacoemulsification procedure. II. Corneal endothelial changes.

Authors:  F M Polack; A Sugar
Journal:  Invest Ophthalmol       Date:  1976-06

3.  Endothelial cell counts with and without phacoemulsification.

Authors:  K J Hoffer
Journal:  Ophthalmology       Date:  1979-11       Impact factor: 12.079

4.  Viscous corneal protection by sodium hyaluronate, chondroitin sulfate, and methylcellulose.

Authors:  M E Hammer; T G Burch
Journal:  Invest Ophthalmol Vis Sci       Date:  1984-11       Impact factor: 4.799

5.  [Endothelial cell defects caused by ultrasound phacoemulsification in a model].

Authors:  H Bleckmann; T Seiler
Journal:  Fortschr Ophthalmol       Date:  1985

6.  Specular microscopy in cataract and intraocular lens patients. A report of 564 cases.

Authors:  M C Kraff; D R Sanders; H L Lieberman
Journal:  Arch Ophthalmol       Date:  1980-10

7.  Effects of phacoemulsification and extracapsular lens removal on corneal thickness and endothelial cell density in the dog.

Authors:  R M Gwin; J K Warren; D A Samuelson; G G Gum
Journal:  Invest Ophthalmol Vis Sci       Date:  1983-02       Impact factor: 4.799

8.  [Phacoemulsification and corneal endothelium: experimental study by scanning microscopy (author's transl)].

Authors:  G Renard; J C Cornic; O Trouve; M Hirsch; Y Pouliquen
Journal:  J Fr Ophtalmol       Date:  1980       Impact factor: 0.818

9.  A comparison of the effects of phacoemulsification and nucleus expression on endothelial cell density.

Authors:  J M Graether; J A Davison; G W Harris; R H Watt; R R Widner; V Sposito
Journal:  J Am Intraocul Implant Soc       Date:  1983

10.  [Phakoemulsification using the Girard apparatus. Experimental study of the effects on the corneal endothelium of the rabbit].

Authors:  J M Chansel; F M Polack
Journal:  Arch Ophtalmol (Paris)       Date:  1976 Aug-Sep
View more