Literature DB >> 3758101

Combined evaluation of first-pass radionuclide angiography and equilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. I. Results at rest.

P Knesewitsch, E Kleinhans, U Buell.   

Abstract

The results of 203 patients who underwent first-pass radionuclide angiography (FP), as well as quantitative equilibrium radionuclide ventriculography (qERNV), were stored in a data base system and evaluated statistically. In patients with coronary artery disease (CAD) without previous myocardial infarction (MI), evaluation of global and regional ejection fraction (gEF, rEF) at rest revealed a poor sensitivity of 64% (Rest-qERNV) and 69% (Rest-FP), respectively. In patients with a history of one previous MI, the sensitivity of both methods was equivalent: FP 87% and qERNV 84%. In patients with several MIs, sensitivity was higher than 90%. Concerning localization of MI, remarkable differences between FP and qERNV were found. In posterior wall infarction, the FP sensitivity was 87% and qERNV only 67%, whereas in anterior wall infarction, the results were similar for both methods: 93% (FP) and 96% (qERNV), respectively. Since 30 degrees RAO camera position achieves the best visualization of the anterior and posterior wall, FP is superior to qERNV in the evaluation of posterior wall asynergies. In addition, qERNV often fails to discriminate anterior and posterior wall motion abnormalities.

Entities:  

Mesh:

Year:  1986        PMID: 3758101     DOI: 10.1007/bf00276702

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  8 in total

1.  Value of combined assessment of global and segmental ventricular contraction with right anterior oblique ECG-gated first-pass and left anterior oblique equilibrium radionuclide ventriculography.

Authors:  M J Kelly; V Kalff; D Rose; R W Harper; S T Anderson; A Pitt
Journal:  Eur J Nucl Med       Date:  1985

2.  [The determination of the ejection fraction of the left ventricle by the first passage of an indicator bolus. Comparison of two curve-fitting algorithms (author's transl)].

Authors:  E Kleinhans; U Büll; C M Kirsch
Journal:  Nuklearmedizin       Date:  1980       Impact factor: 1.379

3.  [Regional ejection fractions to determine left ventricular function. Comparison of first-radionuclide-pass and equilibrium-radionuclide-ventriculography with the results of cineventriculography].

Authors:  M Seiderer; E Kleinhans; U Büll; B E Strauer
Journal:  Rofo       Date:  1982-10

4.  [Quantitative resting radionuclide-ventriculography for multifactorial analysis of left ventricular function].

Authors:  P Knesewitsch; E Kleinhans; M Seiderer; M Klepzig; U Büll
Journal:  Nuklearmedizin       Date:  1984-08       Impact factor: 1.379

5.  Impaired left ventricular diastolic filling in patients with coronary artery disease: assessment with radionuclide angiography.

Authors:  R O Bonow; S L Bacharach; M V Green; K M Kent; D R Rosing; L C Lipson; M B Leon; S E Epstein
Journal:  Circulation       Date:  1981-08       Impact factor: 29.690

6.  Influence of background and absorption correction on nuclear quantification of left ventricular end-diastolic volume.

Authors:  M Seiderer; I Bohn; U Buell; E Kleinhans; B E Strauer
Journal:  Br J Radiol       Date:  1983-03       Impact factor: 3.039

7.  [Quantitative equilibrium radionuclide ventriculography at rest in the evaluation of the severity of coronary disease].

Authors:  P Knesewitsch; E Kleinhans; M Seiderer; R Doliwa; U Büll
Journal:  Nuklearmedizin       Date:  1984-02       Impact factor: 1.379

8.  Resting early peak diastolic filling rate: a sensitive index of myocardial dysfunction in patients with coronary artery disease.

Authors:  J F Polak; A J Kemper; J A Bianco; A F Parisi; D E Tow
Journal:  J Nucl Med       Date:  1982-06       Impact factor: 10.057

  8 in total
  4 in total

1.  Analysis of left ventricular function from gated first-pass and multiple gated equilibrium acquisitions.

Authors:  P Vainio; J Jurvelin; J Kuikka; E Vanninen; E Länsimies
Journal:  Int J Card Imaging       Date:  1992

2.  Assessment of ventricular function with first-pass radionuclide angiography using technetium 99m hexakis-2-methoxyisobutylisonitrile: a European multicentre study.

Authors:  G Bisi; R Sciagrà; U Büll; K E Britton; C Eilles; D Eissner; K Hahn; H Höffken; K Joseph; J H McKillop
Journal:  Eur J Nucl Med       Date:  1991

3.  Combined evaluation of first pass radionuclide angiography and equilibrium radionuclide ventriculography in the diagnosis of coronary artery disease. II. Results during exercise.

Authors:  P Knesewitsch; S Fritsch; E Kleinhans; U Büll
Journal:  Eur J Nucl Med       Date:  1987

4.  99mTc-MIBI (RP-30) to define the extent of myocardial ischemia and evaluate ventricular function.

Authors:  M P Larock; R Cantineau; V Legrand; H Kulbertus; P Rigo
Journal:  Eur J Nucl Med       Date:  1990
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.