Use of the loss-tangent function in dielectric spectroscopy.

A Surowiec, S S Stuchly.   

Abstract

A new method for finding the dielectric parameters of biological substances is presented. The method makes use of the loss-tangent as a function of frequency to identify the dominating relaxation process. The method was tested for a few cell suspensions (blood and lymphocytes) and two tissues (liver and spleen). The obtained parameters agree well with those calculated from Maxwell-Wagner theory (beta dispersion).

Mesh:

Year:  1986        PMID: 3753530     DOI: 10.1002/bem.2250070303