Literature DB >> 3747551

Simple and precise method for counting ciliary beats directly from the TV monitor screen.

P C Braga, G Dall'Oglio, R Bossi, L Allegra.   

Abstract

The modern optical microscopic technique together with the use of the small perfusion chamber allows the maintenance and observation of isolated ciliated epithelia for many hours in vitro. Counting ciliary beats is a good means for evaluating the behavior of these cells immediately under different environmental conditions and also for evaluating the pharmacologic or toxic action of drugs. Using a TV camera joined to a microscope equipped with the Nomarsky differential interference contrast set, it is possible to see on a TV monitor an image of the cilia at a very high magnification (over 1000 X), with a good resolution. This paper describes a method and an instrument, with a digital readout purposely designed to receive and count signals from a phototransistor placed directly on the protective screen of the TV monitor to correspond exactly with the point of passage of the coming and going movement of the selected cilia. In this way, it is possible to obtain (in real time and in a simple way through visual observation of the beat) the final count, which consists of the number of passages, in a prefixed time, in front of the phototransistors of the dark area which represents the ciliary body on the light background.

Mesh:

Substances:

Year:  1986        PMID: 3747551     DOI: 10.1016/0160-5402(86)90021-5

Source DB:  PubMed          Journal:  J Pharmacol Methods        ISSN: 0160-5402


  5 in total

1.  Quantitation of in vitro ciliated cell growth through image analysis.

Authors:  J M Zahm; E Lamiot; D Pierrot; M Chevillard; J Hinnrasky; E Puchelle
Journal:  In Vitro Cell Dev Biol       Date:  1990-11

Review 2.  The nasal mucociliary clearance: relevance to nasal drug delivery.

Authors:  N G Schipper; J C Verhoef; F W Merkus
Journal:  Pharm Res       Date:  1991-07       Impact factor: 4.200

Review 3.  The influence of drugs on nasal ciliary movement.

Authors:  W A Hermens; F W Merkus
Journal:  Pharm Res       Date:  1987-12       Impact factor: 4.200

4.  Variability in ciliary beat frequency in normal subjects and in patients with bronchiectasis.

Authors:  D Veale; A D Rodgers; C J Griffiths; T Ashcroft; G J Gibson
Journal:  Thorax       Date:  1993-10       Impact factor: 9.139

5.  Ciliary beat frequency in transplanted lungs.

Authors:  D Veale; P N Glasper; A Gascoigne; J H Dark; G J Gibson; P A Corris
Journal:  Thorax       Date:  1993-06       Impact factor: 9.139

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.