Literature DB >> 3745701

Programmed electrical stimulation studies for ventricular tachycardia induction in humans. I. The role of ventricular functional refractoriness in tachycardia induction.

L B Mitchell, D G Wyse, H J Duff.   

Abstract

Closely coupled extrastimuli are frequently necessary to induce ventricular tachycardia at electrophysiologic study. Although induction usually requires propagated extrastimuli, systematic evaluations of minimal coupling intervals have focused on nonpropagated measures (effective refractory periods) rather than on propagated measures (functional refractory periods). The effects of procedural factors on ventricular functional refractory periods were examined in 10 patients. Like the effective refractory period, the functional refractory period shortens with rapid pacing cycle lengths (281 +/- 12 ms at a cycle length of 600 ms; 260 +/- 15 ms at a cycle length of 400 ms) and with multiple extrastimuli (279 +/- 16 ms with one extrastimulus; 214 +/- 16 ms with two extrastimuli). The effects of multiple extrastimuli exceed those of shortening pacing cycle length. Unlike the effective refractory period, the functional refractory period is affected by recording site (increasing as the distance from the pacing site increases) but is not affected by increasing the stimulus intensity above twice diastolic threshold (282 +/- 14 ms at 2 times threshold; 282 +/- 13 ms at 16 times threshold) or by increasing the pulse width above 2 ms (282 +/- 13 ms at a pulse width of 2 ms; 282 +/- 14 ms at a pulse width of 5 ms). The effect of varying stimulus intensity on ventricular tachycardia induction was examined in a second group of 11 patients with documented, spontaneous ventricular tachycardia. No change in ventricular tachycardia inducibility accompanied changes in stimulus intensity from 2 to 10 times threshold.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3745701     DOI: 10.1016/s0735-1097(86)80184-x

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  5 in total

1.  Divergence of endocardial QT interval components during programmed electrical stimulation including observations during induction of sustained ventricular tachyarrhythmias.

Authors:  D G Wyse; L B Mitchell; R S Sheldon; A M Gillis; H J Duff
Journal:  J Interv Card Electrophysiol       Date:  1997-02       Impact factor: 1.900

Review 2.  Can antiarrhythmic agents be selected based on mechanism of action?

Authors:  W Lau; D Newman; P Dorian
Journal:  Drugs       Date:  2000-12       Impact factor: 9.546

Review 3.  Can the technicalities of electrophysiological testing for ventricular tachycardia be simplified?

Authors:  D E Ward
Journal:  Br Heart J       Date:  1987-11

4.  QT dispersion and diastolic functions in differential diagnosis of primary mitral valve prolapse and rheumatic mitral valve prolapse.

Authors:  Baris Guven; Ayse Guler Eroglu; Kadir Babaoglu; Tevfik Demir; Alper Güzeltas; Funda Oztunc; Levent Saltik
Journal:  Pediatr Cardiol       Date:  2007-10-05       Impact factor: 1.655

5.  Electrical restitution in the endocardium of the intact human right ventricle.

Authors:  J M Morgan; D Cunningham; E Rowland
Journal:  Br Heart J       Date:  1992-01
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.