Literature DB >> 373924

Instantaneous blood flow responses to positive end-expiratory pressure with spontaneous ventilation.

R A Perschau, C J Pepine, W W Nichols, J B Downs.   

Abstract

Variable hemodynamic responses to positive end-expiratory pressure (PEEP) with spontaneous ventilation have been reported. To clarify these responses, 15 awake patients were studied using a catheter-tip velocity transducer to record phasic aortic root blood flow continuously before, during and after PEEP (10 cm H2O) applied with a face mask. Central blood volume and effective ventricular filling pressures were measured. Phasic pulmonary artery blood flow was also simultaneously recorded in three of these patients. PEEP produced an acute aortic blood flow reduction, detected within one respiratory cycle. Stroke volume decreased 12%, and since heart rate was unchanged, cardiac output also declined (p less than 0.05). Inspiratory-to-expiratory aortic flow changes were less during PEEP. In contrast, inspiratory-to-expiratory pulmonary artery flow alterations were exaggerated due to a marked flow decline during expiration. Central blood volume and effective left ventricular filling pressure decreased 9% and 19%, respectively (p less than 0.05 in all patients). The decrease in pulmonary artery flow was associated with a decrease in central blood volume in the three patients in whom pulmonary flow was measured. PEEP promptly reduces cardiac output during spontaneous ventilation, related to a decrease in pulmonary flow in expiration.

Entities:  

Mesh:

Year:  1979        PMID: 373924     DOI: 10.1161/01.cir.59.6.1312

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  4 in total

1.  A comparative study of the cardiorespiratory effects of continuous positive airway pressure breathing and continuous positive pressure ventilation in acute respiratory failure.

Authors:  G Simonneau; F Lemaire; A Harf; J Carlet; B Teisseire
Journal:  Intensive Care Med       Date:  1982-03       Impact factor: 17.440

2.  [The effect of PEEP ventilation on hemodynamics and regional blood flow (author's transl)].

Authors:  J Beyer; K Messmer
Journal:  Klin Wochenschr       Date:  1981-12-01

3.  Aortic input impedance during nitroprusside infusion. A reconsideration of afterload reduction and beneficial action.

Authors:  C J Pepine; W W Nichols; R C Curry; C R Conti
Journal:  J Clin Invest       Date:  1979-08       Impact factor: 14.808

Review 4.  Organ-specific support in multiple organ failure: pulmonary support.

Authors:  P S Barie
Journal:  World J Surg       Date:  1995 Jul-Aug       Impact factor: 3.352

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.