Literature DB >> 3738421

Technical parameters of plastics (Mercox CL-2B and various methylmethacrylates) used in scanning electron microscopy of vascular corrosion casts.

T Weiger, A Lametschwandtner, P Stockmayer.   

Abstract

The most frequently used resins for vascular corrosion casting Mercox Cl-2B, Mercox Cl-2B diluted with methylmethacrylate (MMA) monomer and various self prepared MMA and hydroxypropyl-methacrylate mixtures were tested with regard to their thermostability, shrinkage, viscosity and replication quality. It was found that tempering of the plastics improves their thermostability with the exception of Mercox Cl-2B and that shrinkage depends on the amount of monomers a resin contains. In detail; Mercox Cl-2B has the lowest shrinkage (8.018%) whereas a hydroxypropyl-methacrylate mixture possessed the highest (20.408%). But, on the other hand, viscosity decreases with the quantity of monomers. All resins tested were able to replicate structures of 260 nm height but the resins' quality of replication was found to be limited by the effects of shrinkage. Finally, a method to estimate the blood volume of organs and tissues with the help of vascular corrosion casts is given.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3738421

Source DB:  PubMed          Journal:  Scan Electron Microsc        ISSN: 0586-5581


  6 in total

1.  Microvascularization of the human digit as studied by corrosion casting.

Authors:  S Sangiorgi; A Manelli; T Congiu; A Bini; G Pilato; M Reguzzoni; M Raspanti
Journal:  J Anat       Date:  2004-02       Impact factor: 2.610

2.  Deep pulmonary lymphatics in immature lungs.

Authors:  Renée Dickie; Meredith Cormack; Manuela Semmler-Behnke; Wolfgang G Kreyling; Akira Tsuda
Journal:  J Appl Physiol (1985)       Date:  2009-06-25

3.  Choroidal and iris angioarchitecture of the newt: a scanning electron-microscopic study of vascular corrosion casts.

Authors:  M Lazzari; V Franceschini; G Minelli; F Ciani
Journal:  Experientia       Date:  1993-04-15

4.  Structural and spatial organisation of brain parenchymal vessels in the lizard, Podarcis sicula: a light, transmission and scanning electron microscopy study.

Authors:  M Lazzari; V Franceschini
Journal:  J Anat       Date:  2000-08       Impact factor: 2.610

5.  Altered morphology and 3D architecture of brain vasculature in a mouse model for Alzheimer's disease.

Authors:  Eric P Meyer; Alexandra Ulmann-Schuler; Matthias Staufenbiel; Thomas Krucker
Journal:  Proc Natl Acad Sci U S A       Date:  2008-02-27       Impact factor: 11.205

6.  Microvascular anatomy of the non-lobulated liver of adult Xenopus laevis: A scanning electron microscopic study of vascular casts.

Authors:  Alois Lametschwandtner; Udo Spornitz; Bernd Minnich
Journal:  Anat Rec (Hoboken)       Date:  2021-05-24       Impact factor: 2.227

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.