Vacuum extraction: a randomized controlled comparison of the New Generation cup with the original Bird cup.

F Carmody, A Grant, M Somchiwong.   

Abstract

A new design of vacuum extractor cup--'the New Generation cup'--has recently been introduced into clinical practice. Its major modification is a traction cord which passes around the rim of the cup for 180 degrees and is free to slide within the rim. Claims that this design 'enables the operator to pull obliquely without causing the cup to tilt' and thereby 'reduces failure rates, reduces the incidence of scalp trauma and increases operator confidence' have been evaluated in a randomized controlled trial. 123 women with singleton pregnancies of 37 completed weeks or more, with a cephalic presentation and for whom a decision to deliver by vacuum extraction had been taken, were randomly allocated to the 'New Generation' cup or BIRD's original vacuum extractor cup; 50 mm anterior and posterior cups were used in both groups as appropriate. The two groups were comparable at entry and delivered by obstetricians of similar status. The two types of cup were similar in respect of number of failures to deliver with the vacuum extractor, correct positioning of the cup, number of pulls required for delivery and time taken to expedite delivery. Cup detachments occurred in nine cases allocated to the 'New Generation' cup compared with four allocated to the original BIRD cup. The babies in the two groups were in similar condition at birth and sustained similar amounts of scalp trauma. Neonatal jaundice, both clinical and biochemical, was more common in babies delivered with the 'New Generation cup' and this was reflected in greater use of phototherapy in this group. Operators were equally divided in their preference of cup.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1986        PMID: 3735050     DOI: 10.1515/jpme.1986.14.2.95

Source DB:  PubMed          Journal:  J Perinat Med        ISSN: 0300-5577            Impact factor:   1.901


  2 in total

Review 1.  Instruments for assisted vaginal birth.

Authors:  Ganga L Verma; Jessica J Spalding; Marc D Wilkinson; G Justus Hofmeyr; Valerie Vannevel; Fidelma O'Mahony
Journal:  Cochrane Database Syst Rev       Date:  2021-09-24

2.  Features of randomised trials designed by the NPEU Perinatal Trials Service during Adrian Grant's directorship.

Authors:  Diana Elbourne
Journal:  Reprod Health       Date:  2018-07-09       Impact factor: 3.223

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.