| Literature DB >> 3732902 |
M M Mughal, M Marples, J Bancewicz.
Abstract
Computer analysed transit of a liquid bolus containing Tc99m (RT) was compared with manometry for the detection of oesophageal motility disorders in 151 patients with a variety of oesophageal symptoms. Manometry was abnormal in 99 of whom 44 had abnormal RT (sensitivity 44%); it was normal in 52 of whom 37 had normal RT (specificity 71%). The commonest manometric abnormalities were non-specific motility disorders characterised by abnormalities of peristaltic amplitude, waveform or baseline. Radionuclide transit was abnormal in only 32/77 (42%) of these. Achalasia, which is characterised by complete aperistalsis, was the least common diagnosis, but all five cases had abnormal RT. Simultaneous manometry and RT in 30 patients showed that the transit of a liquid bolus through the oesophagus is determined by the propagation rather than the form of the peristaltic contraction. Because non-specific motility disorders are common in clinical practice, RT is not a useful screening test for oesophageal dysmotility.Entities:
Mesh:
Year: 1986 PMID: 3732902 PMCID: PMC1433370 DOI: 10.1136/gut.27.8.946
Source DB: PubMed Journal: Gut ISSN: 0017-5749 Impact factor: 23.059