Literature DB >> 3731995

Telemetry glucose monitoring device with needle-type glucose sensor: a useful tool for blood glucose monitoring in diabetic individuals.

M Shichiri, N Asakawa, Y Yamasaki, R Kawamori, H Abe.   

Abstract

For continuous monitoring of glucose concentration in ambulant diabetic patients, a telemetry glucose monitoring system with a needle-type glucose sensor has been developed. The system consists of a sensor transmitter (4 X 6 X 2 cm, 50 g) that converts current signals generated in a needle-type glucose sensor to high-frequency audio signals and a receiver that continuously calculates glucose concentrations from the received audio signals. The noise range of a monitoring record with the telemetry system (0.3 +/- 0.04%, mean +/- SEM) was significantly smaller than that with a wire-connected system, the wearable artificial endocrine pancreas (2.5 +/- 0.3%). Postprandial tissue glucose concentration responded well to the plasma glucose concentration, with a time lag of 5 min. Continuous glucose monitoring of five diabetic subjects for 77 +/- 22 h revealed that a significant correlation existed between the subcutaneous tissue glucose concentration and the plasma glucose concentration measured simultaneously in each patient. These data indicate the usefulness of the telemetry glucose monitoring system in strict glycemic control of diabetic individuals.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3731995     DOI: 10.2337/diacare.9.3.298

Source DB:  PubMed          Journal:  Diabetes Care        ISSN: 0149-5992            Impact factor:   19.112


  7 in total

Review 1.  Can hypoglycaemia be predicted before its onset?

Authors:  P Lönnroth
Journal:  Diabetologia       Date:  1996-05       Impact factor: 10.122

2.  Minimizing the impact of time lag variability on accuracy evaluation of continuous glucose monitoring systems.

Authors:  Cosimo Scuffi; Fausto Lucarelli; Francesco Valgimigli
Journal:  J Diabetes Sci Technol       Date:  2012-11-01

Review 3.  [Normoglycemia as a therapy goal in diabetes treatment--concept and realization].

Authors:  E G Siegel
Journal:  Klin Wochenschr       Date:  1990-03-16

4.  Automated feedback control of subcutaneous glucose concentration in diabetic dogs.

Authors:  K Rebrin; U Fischer; T von Woedtke; P Abel; E Brunstein
Journal:  Diabetologia       Date:  1989-08       Impact factor: 10.122

5.  Interstitium versus Blood Equilibrium in Glucose Concentration and its Impact on Subcutaneous Continuous Glucose Monitoring Systems.

Authors:  Cosimo Scuffi
Journal:  Eur Endocrinol       Date:  2014-02-28

6.  Glucose-responsive gel from phenylborate polymer and poly(vinyl alcohol): prompt response at physiological pH through the interaction of borate with amino group in the gel.

Authors:  I Hisamitsu; K Kataoka; T Okano; Y Sakurai
Journal:  Pharm Res       Date:  1997-03       Impact factor: 4.200

Review 7.  Biocompatible materials for continuous glucose monitoring devices.

Authors:  Scott P Nichols; Ahyeon Koh; Wesley L Storm; Jae Ho Shin; Mark H Schoenfisch
Journal:  Chem Rev       Date:  2013-02-07       Impact factor: 60.622

  7 in total