Effects of endotracheal tube leaks on functional residual capacity determination in intubated neonates.

W W Fox, J G Schwartz, T H Shaffer.   

Abstract

The present study evaluates a new closed circuit helium (He) dilution technique for determination of endotracheal (ET) tube leakage and functional residual capacity (FRC) in neonates with ET tubes. By analytically relating the fall in He concentration due to mixing with that due to leakage, it is possible to predict the final equilibration concentration of He and, therefore, correct for ET tube leaks. The system (120 ml) contains an air pump, He meter, breathing bag in cyclinder, a strip chart readout, and solenoid valve. Continuous positive airway pressure (CPAP) or ventilator pressure can be applied during testing. FRC measurements were performed on 13 neonates (799--4500 g) on CPAP with ET tubes. Leak rates were significantly higher (P less than 0.001) on 3 cm H2O CPAP compared to O cm H2O CPAP. The mean measured FRC was 53.5 ml at 3 cm H2O and 46.3 ml at 0 cm H2O CPAP. If gas leakage had not been considered in FRC calculations, the error in FRC could have been as high as 39% at 3 cm H2O CPAP and 18% at 0 cm H2O CPAP.

Entities:  

Mesh:

Substances:

Year:  1979        PMID: 372911     DOI: 10.1203/00006450-197901000-00013

Source DB:  PubMed          Journal:  Pediatr Res        ISSN: 0031-3998            Impact factor:   3.756


  5 in total

Review 1.  Neonatal non-invasive respiratory support: physiological implications.

Authors:  Thomas H Shaffer; Deepthi Alapati; Jay S Greenspan; Marla R Wolfson
Journal:  Pediatr Pulmonol       Date:  2012-07-06

2.  A 133-xenon inhalation system for cerebral blood-flow measurements in ventilated premature babies.

Authors:  A E Lipp-Zwahlen; J Magestretti; J Thompson; P Titcomb; S Treves
Journal:  Eur J Nucl Med       Date:  1986

3.  Measurement of lung volume and optimal oxygenation during high frequency oscillation.

Authors:  G Dimitriou; A Greenough
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  1995-05       Impact factor: 5.747

Review 4.  Updates on Functional Characterization of Bronchopulmonary Dysplasia - The Contribution of Lung Function Testing.

Authors:  Anne Greenough; Anoop Pahuja
Journal:  Front Med (Lausanne)       Date:  2015-05-29

Review 5.  Infant lung function testing in the intensive care unit.

Authors:  J Hammer; C J Newth
Journal:  Intensive Care Med       Date:  1995-09       Impact factor: 17.440

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.