Literature DB >> 3719948

Use of a new sample-collection device (Macroduct) in anion analysis of human sweat.

D E Cole, M J Boucher.   

Abstract

We compared concentrations of chloride and sulfate in sweat obtained by use of the Macroduct capillary-coil collection device with results obtained by the conventional absorbent filter pad technique. Samples obtained with the device weighed less than those obtained conventionally, but sweat chloride concentrations were not significantly different. To assess analysis of trace anions, we used inorganic sulfate as a prototype. Background contamination, a problem with the filter pads, was negligible with the Macroduct collector. However, with the Macroduct device, sulfate concentrations were nominally higher than with the conventional pads (105 +/- 6 vs 88 +/- 5 mumol/L) and showed no dependence of sulfate concentration on sweat rate. Subtraction of the significant "background" SO4 concentration obtained with blanks (i.e., unused filter pads) is a likely source of error in the conventional method. We consider the Macroduct device useful for study of trace constituents of human sweat.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3719948

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  8 in total

Review 1.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

2.  A new method of sweat testing: the CF Quantum®sweat test.

Authors:  Michael J Rock; Linda Makholm; Jens Eickhoff
Journal:  J Cyst Fibros       Date:  2014-05-23       Impact factor: 5.482

3.  Wearable Electrochemical Alcohol Biosensors.

Authors:  Alan S Campbell; Jayoung Kim; Joseph Wang
Journal:  Curr Opin Electrochem       Date:  2018-05-23

4.  Validity of the Wescor's sweat conductivity analyzer for the assessment of sweat electrolyte concentrations.

Authors:  P Boisvert; V Candas
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1994

Review 5.  Working Up a Good Sweat - The Challenges of Standardising Sweat Collection for Metabolomics Analysis.

Authors:  Joy N Hussain; Nitin Mantri; Marc M Cohen
Journal:  Clin Biochem Rev       Date:  2017-02

6.  Towards Addressing the Body Electrolyte Environment via Sweat Analysis:Pilocarpine Iontophoresis Supports Assessment of Plasma Potassium Concentration.

Authors:  Donato Vairo; Laurie Bruzzese; Marion Marlinge; Lea Fuster; Nabil Adjriou; Nathalie Kipson; Philippe Brunet; Jennifer Cautela; Yves Jammes; Giovanna Mottola; Stephane Burtey; Jean Ruf; Regis Guieu; Emmanuel Fenouillet
Journal:  Sci Rep       Date:  2017-09-18       Impact factor: 4.379

Review 7.  Sweating Rate and Sweat Sodium Concentration in Athletes: A Review of Methodology and Intra/Interindividual Variability.

Authors:  Lindsay B Baker
Journal:  Sports Med       Date:  2017-03       Impact factor: 11.136

Review 8.  Processing Newborn Bloodspot Screening Results for CF.

Authors:  Jürg Barben; Jane Chudleigh
Journal:  Int J Neonatal Screen       Date:  2020-03-25
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.