Literature DB >> 3717617

Prevention of silent aspiration due to leaks around cuffs of endotracheal tubes.

O U Petring, B Adelhøj, B N Jensen, N O Pedersen, N Lomholt.   

Abstract

Significant aspiration may occur around correctly inflated high volume, low pressure endotracheal tube cuffs. The prevention of silent aspiration due to leaks around cuffs of endotracheal tubes was investigated during general anesthesia for hip replacement in 47 patients. The patients were randomly assigned to one of three groups, in which one of three endotracheal tubes of different designs were used for intubation. The following three tubes were used: the red rubber Rüsch tube with low residual volume cuff, inflated to minimum occluding volume; the Mallinckrodt Hi-Lo tube with high residual volume cuff; the NL tube with high residual volume cuff and automatic cuff pressure regulation. The cuffs on the Mallinckrodt and the NL tubes were inflated to 29-31 cm H2O. One hour before termination of the surgical procedure, 1 ml methylene blue dye was injected into the trachea just above the cuff through a thin channel built into the tubes. At termination of the operation, the trachea below the cuff was inspected with a fiberoptic bronchoscope. Aspiration was found in 12.5% with the Rüsch tube, in 31.2% with the Mallinckrodt tube, and in 0% with the NL tube. Our results show that silent aspiration is still a problem with standard endotracheal tubes, but that it may be minimized by use of appropriate tubes, cuffs, and control of cuff inflation.

Entities:  

Mesh:

Year:  1986        PMID: 3717617

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  8 in total

1.  Endotracheal tube cuff--small important part of a big issue.

Authors:  Shai Efrati; Israel Deutsch; Gabriel M Gurman
Journal:  J Clin Monit Comput       Date:  2012-01-03       Impact factor: 2.502

2.  Variables affecting leakage past endotracheal tube cuffs: a bench study.

Authors:  Renée Pitts; Daniel Fisher; Demet Sulemanji; Joseph Kratohvil; Yandong Jiang; Robert Kacmarek
Journal:  Intensive Care Med       Date:  2010-09-18       Impact factor: 17.440

Review 3.  Surgical approaches to aspiration.

Authors:  D W Eisele
Journal:  Dysphagia       Date:  1991       Impact factor: 3.438

4.  Use of ventilator bundle to prevent ventilator associated pneumonia.

Authors:  Sangeet Narang
Journal:  Oman Med J       Date:  2008-04

Review 5.  The pathogenesis of ventilator-associated pneumonia: I. Mechanisms of bacterial transcolonization and airway inoculation.

Authors:  R J Estes; G U Meduri
Journal:  Intensive Care Med       Date:  1995-04       Impact factor: 17.440

6.  Subglottic secretion suction for preventing ventilator-associated pneumonia: an updated meta-analysis and trial sequential analysis.

Authors:  Zhi Mao; Ling Gao; Guoqi Wang; Chao Liu; Yan Zhao; Wanjie Gu; Hongjun Kang; Feihu Zhou
Journal:  Crit Care       Date:  2016-10-28       Impact factor: 9.097

7.  Perioperative hypoxemia is common with horizontal positioning during general anesthesia and is associated with major adverse outcomes: a retrospective study of consecutive patients.

Authors:  C Michael Dunham; Barbara M Hileman; Amy E Hutchinson; Elisha A Chance; Gregory S Huang
Journal:  BMC Anesthesiol       Date:  2014-06-09       Impact factor: 2.217

8.  Evaluation of operating room reverse Trendelenburg positioning and its effect on postoperative hypoxemia, aspiration, and length of stay: a retrospective study of consecutive patients.

Authors:  C Michael Dunham; Barbara M Hileman; Amy E Hutchinson; Tamara Antonaccio; Elisha A Chance; Gregory S Huang; Gregory Szmaj; Kristen Calabro; Cynthia Bishop; Tyson T Schrickel
Journal:  Perioper Med (Lond)       Date:  2017-08-22
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.