Literature DB >> 3717038

Identification and localization of ventricular septal defect by gated magnetic resonance imaging.

D Didier, C B Higgins.   

Abstract

Gated magnetic resonance imaging was performed to identify the morphologic characteristics of the ventricular septum in 17 normal volunteers and to localize a ventricular septal defect (VSD) in 22 patients using the multisectional spin-echo technique (0.35 tesla). Location of VSDs was corroborated by 2-dimensional echocardiography or angiography or both. The 4 portions of the ventricular septum could be easily identified, especially on transverse images. The VSD was visualized in 20 of the 22 patients. The smallest VSD identified was 0.3 cm in diameter. The 2 VSDs not identified were a small membranous VSD under conditions of excessive patient motion, causing poor-quality images, and a VSD in a 3-month-old infant in which a 3-mm gap existed between sections. The exact location of the VSD could be identified in the other 20 patients. The VSD was perimembranous in 10 patients, inlet in 4, complete atrioventricular canal type in 3 and outlet in 6. The outlet consisted of 1 subpulmonic and 5 malalignment defects. Transverse images were most effective for identification of VSD. Thus, magnetic resonance imaging is a useful noninvasive technique for identifying the ventricular septum and assessing VSDs. It has the potential to be an alternative to angiography in patients beyond infancy for definitive diagnosis and localization of VSD before surgery.

Entities:  

Mesh:

Year:  1986        PMID: 3717038     DOI: 10.1016/0002-9149(86)90219-5

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  7 in total

1.  [Clinical indications for the use of cardiac MRI. By the SIRM Study Group on Cardiac Imaging].

Authors:  E Di Cesare; F Cademartiri; I Carbone; A Carriero; M Centonze; F De Cobelli; R De Rosa; P Di Renzi; A Esposito; R Faletti; R Fattori; M Francone; A Giovagnoni; L La Grutta; G Ligabue; L Lovato; R Marano; M Midiri; A Romagnoli; V Russo; F Sardanelli; L Natale; J Bogaert; A De Roos
Journal:  Radiol Med       Date:  2012-11-26       Impact factor: 3.469

Review 2.  Quantification of cardiac function by conventional and cine magnetic resonance imaging.

Authors:  U Sechtem; P Pflugfelder; C B Higgins
Journal:  Cardiovasc Intervent Radiol       Date:  1987       Impact factor: 2.740

3.  Magnetic resonance imaging at a high field strength of ventricular septal defects in infants.

Authors:  E J Baker; V Ayton; M A Smith; J M Parsons; E J Ladusans; R H Anderson; M N Maisey; M Tynan; N L Fagg; P B Deverall
Journal:  Br Heart J       Date:  1989-10

4.  Prevalence and development of additional cardiac abnormalities in 1448 patients with congenital ventricular septal defects.

Authors:  S Glen; J Burns; P Bloomfield
Journal:  Heart       Date:  2004-11       Impact factor: 5.994

5.  Morphological diagnosis of congenital and acquired heart disease by magnetic resonance imaging.

Authors:  L Sieverding; U Klose; J Apitz
Journal:  Pediatr Radiol       Date:  1990

Review 6.  2014 Korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the Korean Society of Cardiology and the Korean Society of Radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean J Radiol       Date:  2014-11-07       Impact factor: 3.500

Review 7.  2014 korean guidelines for appropriate utilization of cardiovascular magnetic resonance imaging: a joint report of the korean society of cardiology and the korean society of radiology.

Authors:  Yeonyee E Yoon; Yoo Jin Hong; Hyung-Kwan Kim; Jeong A Kim; Jin Oh Na; Dong Hyun Yang; Young Jin Kim; Eui-Young Choi
Journal:  Korean Circ J       Date:  2014-11-25       Impact factor: 3.243

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.