Literature DB >> 3717012

Use of tracer gas technique for industrial exhaust hood efficiency evaluation--where to sample?

V Hampl, R Niemelä, S Shulman, D L Bartley.   

Abstract

A tracer gas technique using sulfur hexafluoride (SF6) was developed for the evaluation of industrial exhaust hood efficiency. In addition to other parameters, accuracy of this method depends on proper location of the sampling probe. The sampling probe should be located in the duct at a minimum distance from the investigated hood where the SF6 is dispersed uniformly across the duct cross section. To determine the minimum sampling distance, the SF6 dispersion in the duct in fully developed turbulent flow was studied at four duct configurations frequently found in industry: straight duct, straight duct-side branch, straight duct-one elbow, and straight duct-two elbows combinations. Based on the established SF6 dispersion factor, the minimum sampling distances were determined as follows: for straight duct, at least 50 duct diameters; for straight duct-side branch combination, at least 25 duct diameters; for straight duct-one elbow combination, 7 duct diameters; and for straight duct-two elbow combination, 4 duct diameters. Sampling at (or beyond) these distances minimizes the error caused by the non-homogeneous dispersion of SF6 in the duct and contributes to the accuracy of the tracer gas technique.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3717012     DOI: 10.1080/15298668691389775

Source DB:  PubMed          Journal:  Am Ind Hyg Assoc J        ISSN: 0002-8894


  2 in total

1.  Effect of Carbon Nanotubes Upon Emissions From Cutting and Sanding Carbon Fiber-Epoxy Composites.

Authors:  William A Heitbrink; Li-Ming Lo
Journal:  J Nanopart Res       Date:  2015-08-13       Impact factor: 2.253

2.  Prevention against carbon monoxide poisoning emanating from burning coal briquettes - Generation rate of carbon monoxide and ventilation requirement.

Authors:  Jun Ojima
Journal:  Ind Health       Date:  2021-10-27       Impact factor: 2.707

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.