Literature DB >> 3716003

A new motor-driven surgical probe and its in vitro comparison with the Cavitron Ultrasonic Surgical Aspirator.

K K Chan, D J Watmough, D T Hope, K Moir.   

Abstract

The Cavitron Ultrasonic Surgical Aspirator (CUSA) has been applied in neurosurgery for several years, but its mode of action is not yet clear and its efficiency at removing soft tissue has not been quantified. We describe here how we have measured the rate of removing soft tissue per unit time, taking ox-liver tissue as the test material. A motor-driven vibrator/aspirator has been developed in our laboratory. It has permitted us to examine the effect of varying independently frequency, amplitude of the vibration, and suction pressure on the removal rate. The results of this investigation show that beyond a certain tip acceleration amplitude (about 100 g) the removal rate does not increase significantly. Also the removal rate is more or less independent of vibration amplitude within the range between 300 micron and 1 mm. Our in vitro experiments with the new probe show that a tip acceleration of about 100 g is enough to remove ox-liver tissue and then the rate of removal is comparable to that obtained with the CUSA operating at maximum vibration amplitude. Analysis of the particle size of the debris collected from CUSA and from our motor-driven device shows that the particle size distribution is similar over the range of 0.5 micron less than d less than 250 micron.

Mesh:

Year:  1986        PMID: 3716003     DOI: 10.1016/0301-5629(86)90337-6

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  5 in total

Review 1.  [Problems associated with extraction of tumors in surgical celioscopy].

Authors:  P Sauthier; S Spuhler; P De Grandi
Journal:  Arch Gynecol Obstet       Date:  1993       Impact factor: 2.344

2.  Effectiveness and safety of ultrasonic atherosclerotic plaque ablation: in vitro investigation.

Authors:  C Müller-Leisse; T Schmitz-Rode; U Böhm; S Biesterfeld; G Hollweg; C J Kirkpatrick; R W Günther
Journal:  Cardiovasc Intervent Radiol       Date:  1993 Sep-Oct       Impact factor: 2.740

3.  Ultrastructural and histopathologic findings after pars plana vitrectomy with a new hypersonic vitrector system. Qualitative preliminary assessment.

Authors:  Salvador Pastor-Idoate; Richard Bonshek; Luciane Irion; Isaac Zambrano; Paul Carlin; Aleksandr Mironov; Paul Bishop; David McLeod; Paulo Eduardo Stanga
Journal:  PLoS One       Date:  2017-04-11       Impact factor: 3.240

4.  Live porcine thirty days delayed recovery surgery: Qualitative findings with the hypersonic vitrectomy.

Authors:  Soon Wai Ch'ng; Luciane Dreher Irion; Richard Bonshek; Joseph Shaw; Alessandro Papayannis; Salvador Pastor-Idoate; Paulo Eduardo Stanga
Journal:  PLoS One       Date:  2018-06-01       Impact factor: 3.240

5.  Comparison of effective phacoemulsification time and corneal endothelial cell loss using three different ultrasound frequencies: A randomized controlled trial.

Authors:  Taru Dewan; Praveen K Malik; Preeti Tomar
Journal:  Indian J Ophthalmol       Date:  2022-04       Impact factor: 2.969

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.