Literature DB >> 3712124

Three-dimensional load-displacement curves due to forces on the cervical spine.

M M Panjabi, D J Summers, R R Pelker, T Videman, G E Friedlaender, W O Southwick.   

Abstract

Load-displacement curves were measured for six types of pure force loading of the cervical spine specimens obtained from fresh human cadavers. A new measuring and mounting technique was developed that yielded data for all of the functional spinal units for each specimen tested. All five of the coupled, as well as the main, load-displacement curves were studied. For anterior and posterior shear loadings, the main resulting motions were translation in that direction (1.6 +/- 0.3 and 1.9 +/- 0.3 mm), and the major coupled motions were flexion and extension (3.6 degrees +/- 1.2 degrees and 6.3 degrees +/- 1.2 degrees). The main motions with right and left lateral shear loadings were translations laterally (1.4 +/- 0.3 and 1.6 +/- 0.3 mm), and the major coupled motions were axial rotations (1.5 degrees +/- 0.6 degrees and 2.3 degrees +/- 0.6 degrees) and not lateral bending. For compression and distraction loadings, the main motions were translations in that direction (0.7 +/- 0.3 and 1.1 +/- 0.3 mm), and the major coupled motions were flexion and extension (2.0 degrees +/- 1.0 degrees and 2.8 degrees +/- 1.0 degrees) and lateral bending (1.4 degrees +/- 0.3 degrees and 1.9 degrees +/- 0.3 degrees). The neutral zones for anterior and posterior shear forces were 1.6 +/- 0.2 mm of translation and 5.8 degrees +/- 1.3 degrees of rotation, for lateral shear force 1.4 +/- 0.3 mm and 2.0 degrees +/- 0.5 degrees, and for compression/distraction 0.6 +/- 0.1 mm and 2.8 degrees +/- 0.9 degrees.

Entities:  

Mesh:

Year:  1986        PMID: 3712124     DOI: 10.1002/jor.1100040203

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  16 in total

Review 1.  The relation between geometry and function of the ankle joint complex: a biomechanical review.

Authors:  Roeland P Kleipool; Leendert Blankevoort
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-03-19       Impact factor: 4.342

2.  A history of spine biomechanics. Focus on 20th century progress.

Authors:  T R Oxland
Journal:  Unfallchirurg       Date:  2015-12       Impact factor: 1.000

3.  Cervical facet joint kinematics during bilateral facet dislocation.

Authors:  Manohar M Panjabi; Andrew K Simpson; Paul C Ivancic; Adam M Pearson; Yasuhiro Tominaga; James J Yue
Journal:  Eur Spine J       Date:  2007-06-14       Impact factor: 3.134

4.  Three-dimensional biomechanical properties of the human cervical spine in vitro. II. Analysis of instability after ligamentous injuries.

Authors:  N Wen; F Lavaste; J J Santin; J P Lassau
Journal:  Eur Spine J       Date:  1993-06       Impact factor: 3.134

5.  Reproducibility of global three-dimensional motion during manual atlanto-axial rotation mobilization: an in vitro study.

Authors:  Erik Cattrysse; Steven Provyn; Patrick Kool; Jan Pieter Clarys; Peter Van Roy
Journal:  J Man Manip Ther       Date:  2010-03

6.  Evaluation of effectiveness of a facet wiring technique: an in vitro biomechanical investigation.

Authors:  V K Goel; C R Clark; K G Harris; Y E Kim; K R Schulte
Journal:  Ann Biomed Eng       Date:  1989       Impact factor: 3.934

7.  Primary and coupled motions after cervical total disc replacement using a compressible six-degree-of-freedom prosthesis.

Authors:  A G Patwardhan; M N Tzermiadianos; P P Tsitsopoulos; L I Voronov; S M Renner; M L Reo; G Carandang; K Ritter-Lang; R M Havey
Journal:  Eur Spine J       Date:  2010-09-24       Impact factor: 3.134

8.  Three-dimensional biomechanical properties of the human cervical spine in vitro. I. Analysis of normal motion.

Authors:  N Wen; F Lavaste; J J Santin; J P Lassau
Journal:  Eur Spine J       Date:  1993-06       Impact factor: 3.134

9.  Stabilizing effect of the transferred conjoined tendon on shoulder stability.

Authors:  Lei-Sheng Jiang; Yi-Min Cui; Zhi-De Zhou; Li-Yang Dai
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-12-23       Impact factor: 4.114

10.  Three-dimensional analysis of cervical spine segmental motion in rotation.

Authors:  Xiong Zhao; Zi-Xiang Wu; Bao-Jun Han; Ya-Bo Yan; Yang Zhang; Wei Lei
Journal:  Arch Med Sci       Date:  2013-05-27       Impact factor: 3.318

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.