Literature DB >> 3711520

Combined use of warfarin and adjusted subcutaneous heparin during pregnancy in patients with an artificial heart valve.

P K Lee, R Y Wang, J S Chow, K L Cheung, V C Wong, T K Chan.   

Abstract

Adjusted subcutaneous heparin was used for thromboembolism prophylaxis during 18 pregnancies in 16 women with an artificial heart valve. Oral warfarin was replaced by subcutaneous heparin as soon as pregnancy was confirmed. The dosage of heparin was adjusted to maintain a partial thromboplastin time at 1.5 times the control value and treatment was administered during the first trimester and the last 3 weeks of gestation. Warfarin was used between the 13th and 37th week. There were no maternal thromboembolic complications and none of the live-born infants showed congenital malformations, indicating that this regimen is effective. However, there were nine spontaneous abortions, including five that occurred in the first 12 weeks. The early abortions were probably related to warfarin exposure at the beginning of pregnancy. The preconception replacement of warfarin by heparin in these patients may be indicated.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3711520     DOI: 10.1016/s0735-1097(86)80116-4

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  8 in total

1.  Use of warfarin during pregnancy.

Authors:  Shirin Abadi; Adrienne Einarson; Gideon Koren
Journal:  Can Fam Physician       Date:  2002-04       Impact factor: 3.275

Review 2.  Anticoagulants in pregnancy.

Authors:  C M Oakley
Journal:  Br Heart J       Date:  1995-08

Review 3.  Care of the pregnant patient with medical illness.

Authors:  J L Carson; D L Elliot
Journal:  J Gen Intern Med       Date:  1988 Nov-Dec       Impact factor: 5.128

Review 4.  Antithrombotic therapy for prosthetic valves: routine treatment and special considerations.

Authors:  A M Al-Ahmad; D Hartnett-Daudelin; D N Salem
Journal:  Curr Cardiol Rep       Date:  2001-01       Impact factor: 2.931

5.  Anticoagulation in pregnant women with mechanical heart valve prostheses.

Authors:  S S Meschengieser; C G Fondevila; M T Santarelli; M A Lazzari
Journal:  Heart       Date:  1999-07       Impact factor: 5.994

6.  Outcome of pregnancy in women with valve prostheses.

Authors:  E Sbarouni; C M Oakley
Journal:  Br Heart J       Date:  1994-02

Review 7.  Long-term anticoagulation. Indications and management.

Authors:  B M Stults; W H Dere; T H Caine
Journal:  West J Med       Date:  1989-10

8.  Anticoagulation therapy in pregnant women with mechanical heart valve.

Authors:  Hakkı Zafer İşcan; Muhammet Onur Hanedan; Anıl Özen; Adem Diken; Veysel Başar; Ertekin Utku Ünal; Cemal Levent Birincioğlu
Journal:  Turk Gogus Kalp Damar Cerrahisi Derg       Date:  2018-01-09       Impact factor: 0.332

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.