Literature DB >> 3697639

Significance of dipstick haematuria. 1. Correlation with microscopy of the urine.

J P Arm, E B Peile, D J Rainford, P W Strike, R E Tettmar.   

Abstract

The reliability of a chemical test for haematuria has been evaluated in patients referred for investigation of suspected renal or urological disease. Red blood cells in concentrations of 10/microliter or greater were found in 24% of urines giving a negative dipstick result, 82% of urines giving a trace positive result and nearly 100% of urines giving dipstick results greater than this. The accuracy of the reagent strip in predicting the presence or absence of significant haematuria was improved by testing several urines from each patient. On the basis of this study, if significant haematuria is present, reagent strip urine testing is an efficient method for its detection.

Entities:  

Mesh:

Substances:

Year:  1986        PMID: 3697639     DOI: 10.1111/j.1464-410x.1986.tb09029.x

Source DB:  PubMed          Journal:  Br J Urol        ISSN: 0007-1331


  8 in total

Review 1.  Haematuria.

Authors:  A G Rockall; A P Newman-Sanders; M A al-Kutoubi; J A Vale
Journal:  Postgrad Med J       Date:  1997-03       Impact factor: 2.401

2.  Unexplained haematuria.

Authors:  M P de Caestecker; F W Ballardie
Journal:  BMJ       Date:  1990-11-24

3.  Detecting bladder cancer.

Authors:  R Plail
Journal:  BMJ       Date:  1990-09-22

4.  Microhaematuria in general practice: is urine microscopy misleading?

Authors:  A C Dowell; J P Britton
Journal:  Br J Gen Pract       Date:  1990-02       Impact factor: 5.386

5.  [Methods and current significance of the evaluation of microscopic haematuria].

Authors:  P Hüppe; F Wawroschek
Journal:  Urologe A       Date:  2011-03       Impact factor: 0.639

Review 6.  [Hematuria in cases of bladder cancer].

Authors:  F Wawroschek; S Roth
Journal:  Urologe A       Date:  2003-02-25       Impact factor: 0.639

7.  Diagnostic accuracy of semiquantitative point of care urine albumin to creatinine ratio and urine dipstick analysis in a primary care resource limited setting in South Africa.

Authors:  June Fabian; Jaya A George; Sean D Currin; Mwawi S Gondwe; Nokthula B Mayindi; Shingirai Chipungu; Bongekile L Khoza; Stephen Tollman
Journal:  BMC Nephrol       Date:  2021-03-20       Impact factor: 2.388

8.  Dipstick haematuria: its association with smoking and nonsteroidal anti-inflammatory drugs.

Authors:  J P Britton; A C Dowell; P Whelan
Journal:  J R Soc Med       Date:  1990-03       Impact factor: 18.000

  8 in total