Literature DB >> 3690019

Methodological factors in the variability of lung volume and specific airway resistance measured by body plethysmography.

R Peslin1, C Gallina, M Rotger.   

Abstract

Thoracic gas volume (TGV) and specific airway resistance (sRaw) are commonly measured using pressure type and flow type body plethysmographs. Within-subject variability of the data, defined as the coefficient of variation of eight to ten measurements during the same session, was assessed with the two kinds of instruments and compared in fifteen normal subjects. The reproducibility of data obtained several days apart was also compared. All measurements were made in a 480-l body chamber, which could be used in both the pressure and the flow mode. The signals were processed digitally using three different algorithms: 1) simple linear regression (LR); 2) linear regression with drift correction achieved by adding to, or subtracting from the plethysmographic signal a term proportional to time (LRC); 3) Fourier analysis (FFT). Within-subject variability of TGV was much larger with flow than with pressure plethysmography when the signals were processed by LR (14.5 +/- 7.5 vs 6.3 +/- 3.0%; p less than 0.001), but almost the same using LRC (6.7 +/- 3.2 vs 5.4 +/- 2.7%) and FFT (6.1 +/- 2.4 vs 5.0 +/- 2.4%). For sRaw, variabilities were larger and less influenced by methodological factors. Adequate digital processing may therefore largely remedy the inherently greater variability of TGV measurements with flow plethysmographs.

Entities:  

Mesh:

Year:  1987        PMID: 3690019

Source DB:  PubMed          Journal:  Bull Eur Physiopathol Respir        ISSN: 0395-3890


  4 in total

1.  Approach to the estimation of alveolar pressure from noninvasive measurement of upper airway resistance.

Authors:  P Gizdulich
Journal:  Med Biol Eng Comput       Date:  1992-05       Impact factor: 2.602

2.  Lung function, maximum and submaximum exercise testing in COPD patients: reproducibility over a long interval.

Authors:  A Noseda; J P Carpiaux; T Prigogine; J Schmerber
Journal:  Lung       Date:  1989       Impact factor: 2.584

3.  Non-linear parameters of specific resistance loops to characterise obstructive airways diseases.

Authors:  Marko Topalovic; Vasileios Exadaktylos; Thierry Troosters; Geert Celis; Jean-Marie Aerts; Wim Janssens
Journal:  Respir Res       Date:  2017-01-09

4.  A Calibration Device to Compare Body Plethysmographs Among Pediatric Lung Function Laboratories.

Authors:  Bruno Demoulin; Iulia Ioan; Claude Duvivier; Claude Bonabel; Cyril Schweitzer; François Marchal; Silvia Demoulin-Alexikova
Journal:  Front Physiol       Date:  2018-10-09       Impact factor: 4.566

  4 in total