Literature DB >> 3684117

An evaluation of the Gore-Tex surgical membrane for the prevention of postoperative peritoneal adhesions.

J M Goldberg1, A A Toledo, D E Mitchell.   

Abstract

The Gore-Tex surgical membrane, expanded polytetrafluoroethylene, has been used as a pericardial graft with minimal adhesion formation reported. The purpose of this study was to assess its efficacy as a barrier method for diminishing postoperative peritoneal adhesions in an animal model. Fifteen New Zealand white rabbits underwent laparotomy, with scrape and cut lesions created bilaterally on the uterine body and horns, respectively. On one side, the lesions were covered with the graft using 7-0 Gore-Tex suture; the contralateral side served as an internal control. After four weeks, the adhesions were graded and mean adhesion scores were calculated. The Gore-Tex score was 4.1 times higher than the control for scrape lesions and 1.9 times higher for cut lesions, but the difference was not statistically significant in either case. Overall, the Gore-Tex mean adhesion score was 2.3 times higher than the control, a statistically significant difference. The Gore-Tex surgical membrane did not appear to be an effective adjuvant for postoperative adhesion prophylaxis in this animal model.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3684117

Source DB:  PubMed          Journal:  Obstet Gynecol        ISSN: 0029-7844            Impact factor:   7.661


  3 in total

1.  Ultrasound detection of visceral adhesion after intraperitoneal ventral hernia treatment: a comparative study of protected versus unprotected meshes.

Authors:  J P Arnaud; S Hennekinne-Mucci; P Pessaux; J J Tuech; C Aube
Journal:  Hernia       Date:  2003-02-25       Impact factor: 4.739

2.  Intraperitoneal treatment of incisional and umbilical hernias using an innovative composite mesh: four-year results of a prospective multicenter clinical trial.

Authors:  J G Balique; S Benchetrit; J L Bouillot; J B Flament; C Gouillat; P Jarsaillon; M Lepère; G Mantion; J P Arnaud; E Magne; F Brunetti
Journal:  Hernia       Date:  2004-12-02       Impact factor: 4.739

3.  Functional cine MRI of the abdomen for the assessment of implanted synthetic mesh in patients after incisional hernia repair: initial results.

Authors:  Tanja Fischer; Roland Ladurner; Alexander Gangkofer; Thomas Mussack; Maximilian Reiser; Andreas Lienemann
Journal:  Eur Radiol       Date:  2007-06-05       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.