M LaPlant1, J Parker, B Stewart, M Waner, R C Straight.
Abstract
The purpose of this study is to compare the optical transmission of the pulsed gold vapor laser (628 nm) to that of the continuous wave argon-pumped dye laser (630 nm) in a homogenous tissue model. Gluteal muscle was taken from a rabbit, and sections of varying thicknesses were made. The tissue samples were positioned at the aperture of an integrating sphere. The laser light was passed through an optical attenuator, coupled to a 600-microns fiber, and then directed onto the surface of the tissue. Transmitted light was collected by the integrating sphere. Light measurements were made with a radiometer. This procedure was repeated for samples of differing thickness using the gold vapor laser as the light source. The identical procedure was performed using the argon-pumped dye laser. No significant difference was found in percent transmission of light using the gold vapor laser as compared to the argon-pumped dye laser.Entities:
Mesh:
Year: 1987 PMID: 3683064 DOI: 10.1002/lsm.1900070407