Literature DB >> 3681529

Contact finite element stress analysis of porous ingrowth acetabular cup implantation, ingrowth, and loosening.

D J Rapperport1, D R Carter, D J Schurman.   

Abstract

Two-dimensional linear and contact finite element analyses were conducted of total hip arthroplasty using metal-backed, porous ingrowth acetabular components. The stress transmission characteristics from the component to the surrounding bone were given special attention. Resultant loads of 20 and 40 degrees medial of vertical were studied, and the influence of adding a metal flange to the rim of the cup was evaluated. The results indicated that when a conventional metal-backed component (without a flange) is initially implanted and subjected to normal loading, these components may experience distraction between the component and the surrounding bone at inferior sites. Compressive stresses in the superior dome cancellous bone, however, will be substantial. If complete porous ingrowth is achieved, the superior dome compressive stresses will be reduced and substantial shear stresses created. In addition, high local bone stresses were found at the component rim. If bone ingrowth is achieved only in specific locations, stress transmission will be dictated by those locations and may differ markedly from the case of complete bone ingrowth. In the event that no porous ingrowth is achieved and a fibrous layer forms around the component, the interface stresses will be similar to those calculated for the natural hip. The addition of a flange to the rim of the cup will reduce the magnitude of the radial stresses transmitted to the cancellous bone superiorly and medially by directly transferring some of the load to the lateral wall of the pelvis. The flange will also help to relieve the high local stresses that are found at the component rim.

Entities:  

Mesh:

Year:  1987        PMID: 3681529     DOI: 10.1002/jor.1100050410

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  4 in total

1.  Long-term results of the threaded Weill cup in primary total hip arthroplasty: a 15-20-year follow-up study.

Authors:  Michael Clarius; Alexander W Jung; Patric Raiss; Marcus R Streit; Christian Merle; Peter R Aldinger
Journal:  Int Orthop       Date:  2009-07-24       Impact factor: 3.075

2.  A comparative study of "plasmacup" and "porous-coated" acetabular components: survival after 10 to 12 years of follow-up.

Authors:  José Ricardo Negreiros Vicente; Carlos Antonio Soares Ulhoa; Marcio Katz; Renato Dainesi Addeo; Alberto Tesconi Croci
Journal:  Clinics (Sao Paulo)       Date:  2010       Impact factor: 2.365

3.  Failure of dual radius hydroxyapatite-coated acetabular cups.

Authors:  Fabio D'Angelo; Mauro Molina; Giacomo Riva; Giovanni Zatti; Paolo Cherubino
Journal:  J Orthop Surg Res       Date:  2008-08-07       Impact factor: 2.359

4.  Biomechanical effect of metal augment and bone graft on cup stability for acetabular reconstruction of total hip arthroplasty in hip dysplasia: a finite element analysis.

Authors:  Yuzhu Wang; Mincong Wang; Chengguo Li; Yoshihiro Nakamura; Liwei Deng; Go Yamako; Etsuo Chosa; Chenglong Pan
Journal:  BMC Musculoskelet Disord       Date:  2022-03-23       Impact factor: 2.362

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.