Literature DB >> 3681358

Methylene blue and indocyanine green artifactually lower pulse oximetry readings of oxygen saturation. Studies in dogs.

A Sidi1, D A Paulus, W Rush, N Gravenstein, R F Davis.   

Abstract

The effects of fluorescein, methylene blue, and indocyanine green on hemodynamic variables and on pulse oximetry and co-oximetry measurements of arterial hemoglobin oxygen saturation (SaO2) and oxyhemoglobin percentage (% HbO2) were evaluated in 16 anesthetized dogs in vitro by co-oximetry (% HbO2) and in vivo by pulse oximetry (SaO2). The light absorbance (optical density) in plasma (range 500 to 800 nm) was measured by a spectrophotometer. Fluorescein did not affect oximetry measurements, plasma light absorbance in the range measured, or hemodynamic variables. Methylene blue caused dose-dependent decreases in measurements made with both forms of oximetry for up to 30 minutes, the decrease being greater and longer lasting with pulse oximetry (P less than 0.05). Hemodynamic measurements in 5 dogs showed that methylene blue (1 to 5 mg/kg) increased arterial pressure transiently, after which cardiac output, stroke index, and left ventricular stroke work index decreased and left ventricular end-diastolic pressure and systemic and pulmonary vascular resistances increased (P less than 0.05 with 5 mg/kg). Methemoglobin concentration measured by co-oximetry increased significantly (to 19.9 +/- 1.4%, P less than 0.05) 1 minute after 5 mg/kg of methylene blue was injected. Methylene blue had a dose- and time-dependent effect on plasma light absorbance, and this effect peaked in the 660- to 670-nm range. The data do not distinguish the relative contributions of physiology (hemodynamic change), chemistry (methemoglobin production), and physics (optical properties) to the decrease in pulse oximetry and co-oximetry measurements that follows injection of methylene blue. Indocyanine green affected neither hemodynamic variables nor co-oximetry readings but decreased pulse oximetry readings for up to 10 minutes dose dependently.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3681358     DOI: 10.1007/bf03337379

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  11 in total

Review 1.  Effects of drugs on clinical laboratory tests.

Authors:  D S Young; L C Pestaner; V Gibberman
Journal:  Clin Chem       Date:  1975-04       Impact factor: 8.327

2.  Oximetry.

Authors:  N J NILSSON
Journal:  Physiol Rev       Date:  1960-01       Impact factor: 37.312

3.  Clinical measurement of circulation time; a comparison of magnesium sulphate and Evans blue dye in normal subjects.

Authors:  T M DEES; J A RUMSFELD; W F MILLER; C B CHAPMAN
Journal:  J Appl Physiol       Date:  1957-05       Impact factor: 3.531

4.  Indicator-dilution curves in acyanotic congenital heart disease.

Authors:  J C BROADBENT; E H WOOD
Journal:  Circulation       Date:  1954-06       Impact factor: 29.690

5.  Effects of intravenously administered dyes on pulse oximetry readings.

Authors:  M S Scheller; R J Unger; M J Kelner
Journal:  Anesthesiology       Date:  1986-11       Impact factor: 7.892

6.  Spurious pulse oximeter desaturation with methylene blue injection.

Authors:  M R Kessler; T Eide; B Humayun; P J Poppers
Journal:  Anesthesiology       Date:  1986-10       Impact factor: 7.892

7.  Evaluation of pulse oximetry.

Authors:  M Yelderman; W New
Journal:  Anesthesiology       Date:  1983-10       Impact factor: 7.892

8.  Spectrophotometric monitoring of arterial oxygen saturation in the fingertip.

Authors:  I Yoshiya; Y Shimada; K Tanaka
Journal:  Med Biol Eng Comput       Date:  1980-01       Impact factor: 2.602

9.  Failure of methylene blue to produce methemoglobinemia in vivo.

Authors:  T P Stossel; R B Jennings
Journal:  Am J Clin Pathol       Date:  1966-05       Impact factor: 2.493

10.  Methylene blue and erythrocytes in the living animal. Contribution to the toxicology of methylene blue and formation of Heinz bodies.

Authors:  G Rentsch; D Wittekind
Journal:  Toxicol Appl Pharmacol       Date:  1967-07       Impact factor: 4.219

View more
  11 in total

Review 1.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

2.  Effects of indigo carmine intravenous injection on noninvasive and continuous total hemoglobin measurement.

Authors:  Tsuyoshi Isosu; Tomohiko Satoh; Rieko Oishi; Tsuyoshi Imaizumi; Takahiro Hakozaki; Shinju Obara; Yukihiro Ikegami; Shin Kurosawa; Masahiro Murakawa
Journal:  J Clin Monit Comput       Date:  2015-06-17       Impact factor: 2.502

Review 3.  Pulse oximetry: analysis of theory, technology, and practice.

Authors:  M W Wukitsch; M T Petterson; D R Tobler; J A Pologe
Journal:  J Clin Monit       Date:  1988-10

4.  Indocyanine green dye administration can cause oxygen desaturation.

Authors:  Kamath Sriganesh; B Vinay; Varadarajan Bhadrinarayan
Journal:  J Clin Monit Comput       Date:  2012-12-19       Impact factor: 2.502

5.  Effects of indigo carmine intravenous injection on oxygen reserve index (ORi™) measurement.

Authors:  Tsuyoshi Isosu; Keisuke Yoshida; Rieko Oishi; Tsuyoshi Imaizumi; Yuzo Iseki; Norie Sanbe; Yukihiro Ikegami; Shinju Obara; Shin Kurosawa; Masahiro Murakawa
Journal:  J Clin Monit Comput       Date:  2017-10-03       Impact factor: 2.502

6.  The values shown on optical technology-based patient monitors must be cautiously interpreted: intravenous dye-induced errors.

Authors:  Hee-Pyoung Park
Journal:  Korean J Anesthesiol       Date:  2015-04

7.  Effects of intravenously administered indocyanine green on near-infrared cerebral oximetry and pulse oximetry readings.

Authors:  Ho Young Baek; Hyun-Jung Lee; Joung Min Kim; Soo-Young Cho; Seongtae Jeong; Kyung Yeon Yoo
Journal:  Korean J Anesthesiol       Date:  2015-03-30

8.  Use of methylene blue and near-infrared fluorescence in thyroid and parathyroid surgery.

Authors:  Sarah L Hillary; Stephanie Guillermet; Nicola J Brown; Sabapathy P Balasubramanian
Journal:  Langenbecks Arch Surg       Date:  2017-12-11       Impact factor: 3.445

9.  Methylene blue treatment in experimental ischemic stroke: a mini review.

Authors:  Zhao Jiang; Timothy Q Duong
Journal:  Brain Circ       Date:  2016

10.  Oxygen reserve index, a new method of monitoring oxygenation status: what do we need to know?

Authors:  Shu-Ting Chen; Su Min
Journal:  Chin Med J (Engl)       Date:  2020-01-20       Impact factor: 2.628

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.