Literature DB >> 3679575

Hemodynamic tolerance and plasma volume variations during plasma exchange. Replacement fluid: albumin alone or albumin plus gelatin?

B Guidet1, L Luquel, C De Labriolle Vaylet, G Offenstadt.   

Abstract

Little is known about mechanisms of systemic hypotension frequently reported during plasma exchange (PE). Type of substitution fluids may interfere with hemodynamic tolerance. In a prospective study, right heart catheterization was performed during 18 PE by filtration with isovolumic substitution. Blood volume was measured with 51Cr tagged erythrocytes and plasma volume (PV) calculated from hematocrit. Substitution fluids were either albumin (A; n = 9) or A + gelatin (A + G; n = 9). In both groups, PE induces significant (p less than 0.01) decreases of mean arterial pressure: group A: - 21 +/- 14%; group A + G: - 23 +/- 15%; of pulmonary wedge pressure: group A: - 41 +/- 33%; group A + G: - 36 +/- 22%; of cardiac index: group A: - 38 +/- 18%; group A + G: - 25 +/- 15%. Plasma volume also decreases after PE: group A: - 13.5 +/- 4%; group A + G: - 18.5 +/- 4%. None of the variations are significantly different between the two groups. So we think that substitution with albumin alone has no advantage for hemodynamic tolerance.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3679575

Source DB:  PubMed          Journal:  Int J Artif Organs        ISSN: 0391-3988            Impact factor:   1.595


  1 in total

1.  The effect of moderate hemodilution with fluosol-DA or normal saline on acetaminophen disposition in the rat.

Authors:  R P Shrewsbury; L G White
Journal:  Experientia       Date:  1990-02-15
  1 in total