Literature DB >> 3674734

Comparison of echocardiographic and radionuclide methods with contrast angiography assessment of left ventricular function--response to isometric exercise in subjects without definite heart disease.

K Groundstroem1, H Huikuri, U Korhonen, M Ikäheimo, J Heikkilä, J Takkunen.   

Abstract

In order to study the validity of non-invasive assessment of left ventricular response to isometric exercise, 21 subjects with chest pain, but without any cardiac abnormalities performed an isometric handgrip test during cardiac catheterization, M-mode echocardiography and radionuclide angiography. Fourteen of the subjects were suitable for comparison of all the three methods. In response to handgrip exercise the ejection fraction (EF) remained unchanged in contrast angiography (68 +/- 9% at rest; 68 +/- 9% during exercise) and echocardiography (74 +/- 4% at rest; 74 +/- 5% during exercise), but showed a small increase on radionuclide angiography (from 57 +/- 5% to 60 +/- 7% (p less than 0.01). Individual changes in ejection fraction during the handgrip exercise had a reasonable correlation between contrast angiography and radionuclide angiography (r = 0.63, p less than 0.01). In order to validate the reproducibility of M-mode echocardiography and radionuclide angiography, the haemodynamic and left ventricular responses during two consecutive handgrip tests were compared in eight subjects. No significant differences were seen in the haemodynamic responses or between the changes in ejection fraction or fractional shortening in the two tests. Thus, in subjects without heart disease the non-invasively determined results of the left ventricular response to the handgrip exercise were similar to those obtained invasively and could be reliably reproduced.

Entities:  

Mesh:

Year:  1987        PMID: 3674734

Source DB:  PubMed          Journal:  Ann Clin Res        ISSN: 0003-4762


  2 in total

1.  Left ventricular dimensions during isometric exercise in aortic valve incompetence assessed by M-mode echocardiography and gated equilibrium radionuclide angiography.

Authors:  K Groundstroem; H Huikuri; U Korhonen; M Ikäheimo; P Torniainen; J Heikkilä; M Linnaluoto; J Takkunen
Journal:  Eur J Nucl Med       Date:  1989

2.  Haemodynamic dose-efficacy of levosimendan in healthy volunteers.

Authors:  J Lilleberg; S Sundberg; M Häyhä; J Akkila; M S Nieminen
Journal:  Eur J Clin Pharmacol       Date:  1994       Impact factor: 2.953

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.