Literature DB >> 3673186

[Intraoperative fatal fat and bone marrow embolism of the lung in implantation of a hip endoprosthesis with polymethylmethacrylate bone cement].

M Hochmeister1, E Fellinger, W Denk, G Laufer.   

Abstract

We report on an intraoperative lethal fat embolism and bone marrow embolism of the lung caused by implantation of hip endoprosthesis using acrylic bone cement. Autopsy revealed massive fat embolism of the lung and multiple bone marrow emboli within branches of the pulmonary arteries. It is concluded that there is a close relationship between implantation of hip endoprosthesis and death because fat embolism and bone marrow embolism was the only available evidence on post mortem examination.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3673186     DOI: 10.1055/s-2008-1044738

Source DB:  PubMed          Journal:  Z Orthop Ihre Grenzgeb        ISSN: 0044-3220


  3 in total

1.  Pathogenesis and prophylaxis of circulatory reactions during total hip replacement.

Authors:  K Wenda; J Degreif; M Runkel; G Ritter
Journal:  Arch Orthop Trauma Surg       Date:  1993       Impact factor: 3.067

2.  [Clinical relevance of fat embolism. Review of the literature].

Authors:  C Hirschnitz; P E Ochsner
Journal:  Unfallchirurgie       Date:  1996-04

3.  Grade III bone cement implantation syndrome in malignant lung cancer patient: a case report.

Authors:  Pawan Kumar Hamal; Puspa Raj Poudel; Janith Singh
Journal:  BMC Anesthesiol       Date:  2018-03-02       Impact factor: 2.217

  3 in total