Literature DB >> 3667171

Flow effects in multislice, spin-echo magnetic resonance imaging. Model, experimental verification, and clinical examples.

D M Williams1, C R Meyer, R J Schreiner.   

Abstract

Flowing blood is responsible for a number of complex effects on clinical magnetic resonance (MR) images. To help elucidate these effects, a computer model of a conventional multislice spin-echo pulse sequence was developed. Using TR, TE, and direction of slice acquisition, the model calculates and plots a profile of MR signal intensity vs. z-axis velocity. The model predicts complex profiles with multiple segments of MR signal loss depending on TR, TE, direction of flow, sequence and timing of slice excitation, and slice location relative to adjacent slices. Model predictions were verified by imaging a bulk-flow phantom, consisting of a rotating cylinder filled with a manganese chloride solution with T1 = 840 msec and characterized by a velocity-gradient resolution of 0.23 cm/sec/pixel. In conventional spin-echo MRI of medium and large vessels using body coils, in which the velocity gradients exceed 2-5 cm/sec/pixel, most of the flow artifacts are averaged and are difficult to appreciate. However, bright crescents or rings of MR signal occasionally are seen in the inferior vena cava and portal vein, which the model is invoked to explain. The bulk-flow phantom will find use as a tool for calibrating flow-sensitive pulse sequences when these become widely available.

Entities:  

Mesh:

Year:  1987        PMID: 3667171     DOI: 10.1097/00004424-198708000-00005

Source DB:  PubMed          Journal:  Invest Radiol        ISSN: 0020-9996            Impact factor:   6.016


  4 in total

1.  Brain MR perfusion-weighted imaging with alternate ascending/descending directional navigation.

Authors:  Sung-Hong Park; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2010-09-21       Impact factor: 4.668

2.  Alternate ascending/descending directional navigation approach for imaging magnetization transfer asymmetry.

Authors:  Sung-Hong Park; Timothy Q Duong
Journal:  Magn Reson Med       Date:  2010-07-30       Impact factor: 4.668

3.  Inter-Slice Blood Flow and Magnetization Transfer Effects as A New Simultaneous Imaging Strategy.

Authors:  Paul Kyu Han; Jeffrey W Barker; Ki Hwan Kim; Seung Hong Choi; Kyongtae Ty Bae; Sung-Hong Park
Journal:  PLoS One       Date:  2015-10-14       Impact factor: 3.240

4.  Feasibility of Quantifying Arterial Cerebral Blood Volume Using Multiphase Alternate Ascending/Descending Directional Navigation (ALADDIN).

Authors:  Ki Hwan Kim; Seung Hong Choi; Sung-Hong Park
Journal:  PLoS One       Date:  2016-06-03       Impact factor: 3.240

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.