Tissue substitutes in experimental radiation physics.

D R White.   

Abstract

In this review of tissue substitute materials, the historical development of the important systems is traced from the early 1900's. Tabulations of the constituents, elemental compositions, specific gravities, and the photon and electron interaction characteristics of 64 materials are given together with recommendations of systems having useful simulation properties. Formulation and manufacturing procedures are described and possible future developments in both materials and phantom research are outlined.

Mesh:

Year:  1978        PMID: 366367     DOI: 10.1118/1.594456

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  20 in total

1.  Study of subchondral bone adaptations in a rodent surgical model of OA using in vivo micro-computed tomography.

Authors:  D D McErlain; C T G Appleton; R B Litchfield; V Pitelka; J L Henry; S M Bernier; F Beier; D W Holdsworth
Journal:  Osteoarthritis Cartilage       Date:  2007-09-27       Impact factor: 6.576

2.  Pitfalls in interventional X-ray organ dose assessment-combined experimental and computational phantom study: application to prostatic artery embolization.

Authors:  Philipp Roser; Annette Birkhold; Xia Zhong; Philipp Ochs; Elizaveta Stepina; Markus Kowarschik; Rebecca Fahrig; Andreas Maier
Journal:  Int J Comput Assist Radiol Surg       Date:  2019-08-03       Impact factor: 2.924

3.  Precise measurement of vertebral bone density using computed tomography without the use of an external reference phantom.

Authors:  S D Boden; D J Goodenough; C D Stockham; E Jacobs; T Dina; R M Allman
Journal:  J Digit Imaging       Date:  1989-02       Impact factor: 4.056

4.  A study of effective atomic number and electron density of gel dosimeters and human tissues for scattering of gamma rays: momentum transfer, energy and scattering angle dependence.

Authors:  Murat Kurudirek
Journal:  Radiat Environ Biophys       Date:  2016-08-27       Impact factor: 1.925

5.  Mass attenuation coefficients, quantities and units for use in bone mineral determinations.

Authors:  R Jonson
Journal:  Osteoporos Int       Date:  1993-03       Impact factor: 4.507

6.  Influence of fat on ultrasound measurements of the os calcis.

Authors:  P O Kotzki; D Buyck; D Hans; E Thomas; F Bonnel; F Favier; P J Meunier; M Rossi
Journal:  Calcif Tissue Int       Date:  1994-02       Impact factor: 4.333

7.  Experimentally determined spectral optimization for dedicated breast computed tomography.

Authors:  Nicolas D Prionas; Shih-Ying Huang; John M Boone
Journal:  Med Phys       Date:  2011-02       Impact factor: 4.071

8.  Vertebral bone density in Icelandic women using quantitative computed tomography without an external reference phantom.

Authors:  H Gudmundsdottir; B Jonsdottir; S Kristinsson; A Johannesson; D Goodenough; G Sigurdsson
Journal:  Osteoporos Int       Date:  1993-03       Impact factor: 4.507

9.  Beam hardening artifacts in micro-computed tomography scanning can be reduced by X-ray beam filtration and the resulting images can be used to accurately measure BMD.

Authors:  Jeffrey A Meganck; Kenneth M Kozloff; Michael M Thornton; Stephen M Broski; Steven A Goldstein
Journal:  Bone       Date:  2009-08-06       Impact factor: 4.398

10.  Realistic CT simulation using the 4D XCAT phantom.

Authors:  W P Segars; M Mahesh; T J Beck; E C Frey; B M W Tsui
Journal:  Med Phys       Date:  2008-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.