Literature DB >> 366265

[Suture loosening after keratoplasty and methods for correction (author's transl)].

G Mackensen, H P Haug, C Horn, R Sundmacher, H Witschel.   

Abstract

An analysis of histological and clinical findings in 102 keratoplasties confirms that suture loosening is often associated with defects found in Bowman's membrane and in the superficial stroma. These structures of the cornea serve as the major supporting layer for a suture. In cases of more generally weakened corneal tissue, like in keratokonus, suture loosening is also a relatively frequent occurance. In this paper we report on our experiences with correction methods, post-operative care and immunoprophylaxis after correction.

Mesh:

Year:  1978        PMID: 366265

Source DB:  PubMed          Journal:  Klin Monbl Augenheilkd        ISSN: 0023-2165            Impact factor:   0.700


  3 in total

1.  Suture loosening and gamma sterilization of 10-0 nylon.

Authors:  G van Rij
Journal:  Doc Ophthalmol       Date:  1980-04-15       Impact factor: 2.379

2.  Causes of high astigmatism after penetrating keratoplasty.

Authors:  V P Hoppenreijs; G Van Rij; W H Beekhuis; W J Rijneveld; E Rinkel-van Driel
Journal:  Doc Ophthalmol       Date:  1993       Impact factor: 2.379

3.  [Results of the first 1,000 consecutive elective nonmechanical keratoplasties using the excimer laser. A prospective study over more than 12 years].

Authors:  B Seitz; A Langenbucher; N X Nguyen; M M Kus; M Küchle; G O H Naumann
Journal:  Ophthalmologe       Date:  2004-05       Impact factor: 1.059

  3 in total