An evaluation of six disposable heat and moisture exchangers.

M J Turtle1, A H Ilsley, A J Rutten, W B Runciman.   

Abstract

Six disposable heat and moisture exchangers were tested on patients undergoing anaesthesia requiring mechanical ventilation. Inspiratory humidity and temperature were monitored to find the steady-state values reached with each device together with the times taken for these to be achieved. The exchangers were tested in a non-rebreathing T-piece circuit and in a conventional circle system with a fresh gas flow of 6 l/min: the Siemens 150 provided 28 and 32 mg of water/litre of inspired gas (at about 30 degrees C) in 10 and 5 min respectively, but is rather heavy and bulky. The Portex Humidvent provided 25 and 30 mg/l, and although taking longer to reach steady state (27 and 15 min respectively) is small, light and cheap. The Siemens 151 provided 25 and 27 mg/l in 18 and 10 min respectively, but is heavier than the Portex exchanger. The performances of these three devices were not significantly different from each other in either study (P less than 0.05). For the T-piece system the Pall and Engstrom exchangers were the next most efficient. The Pall device provided 18 and 23 mg/l (in 18 and 8 min respectively) and the Engstrom provided 20 and 23 mg/l (in 19 and 10 min respectively). In the circle system, there were no significant differences between the performances of the Portex, Siemens 151, Pall and Engstrom exchangers. The Pall is also a very effective bacterial filter and has been found to be satisfactory in the intensive care setting. The Terumo appeared to perform no better than a circle system with catheter mount (13 mg/l at 27 degrees C). It would seem that more complex humidification equipment is not necessary during anaesthesia if an efficient heat and moisture exchanger is used.

Entities:  

Mesh:

Year:  1987        PMID: 3661965     DOI: 10.1177/0310057X8701500312

Source DB:  PubMed          Journal:  Anaesth Intensive Care        ISSN: 0310-057X            Impact factor:   1.669


  5 in total

1.  Effects of surgical site and inspired gas warming devices on body temperature during lower abdominal and thoracic surgery.

Authors:  T Harioka; T Sone; K Nomura; M Kakuyama
Journal:  J Anesth       Date:  1992-10       Impact factor: 2.078

2.  Effects of the heat-moisture exchangers on dynamic hyperinflation of mechanically ventilated COPD patients.

Authors:  G Conti; R A De Blasi; M Rocco; P Pelaia; M Antonelli; M Bufi; C Mattia; A Gasparetto
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

3.  A novel method of evaluation of three heat-moisture exchangers in six different ventilator settings.

Authors:  N Unal; J K Kanhai; S L Buijk; J C Pompe; W P Holland; I Gültuna; C Ince; B Saygin; H A Bruining
Journal:  Intensive Care Med       Date:  1998-02       Impact factor: 17.440

4.  Use of heat and moisture exchanging (HME) filters in mechanically ventilated ICU patients: influence on airway flow-resistance.

Authors:  M Chiaranda; L Verona; O Pinamonti; L Dominioni; G Minoja; G Conti
Journal:  Intensive Care Med       Date:  1993       Impact factor: 17.440

5.  Measurement of tracheal temperature is not a reliable index of total respiratory heat loss in mechanically ventilated patients.

Authors:  L Thomachot; X Viviand; P Lagier; J M Dejode; J Albanèse; C Martin
Journal:  Crit Care       Date:  2000-12-08       Impact factor: 9.097

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.