Literature DB >> 3660083

Biomechanical comparison of seven internal fixation devices for the lumbosacral junction.

D W Guyer1, H A Yuan, F W Werner, B E Frederickson, D Murphy.   

Abstract

For comparison purposes, seven different internal fixation systems were applied sequentially to each of six fresh-frozen cadaver spines at the lumbosacral junction. The spines were loaded to a maximum flexion bending moment of 12 Newton meters and an extension moment of 6 Nm. Resultant angular motion was recorded with an electrogoniometer. The Synthes and Kaneda devices provided the most rigid fixation in flexion and extension testing. The Luque internal fixation system was as effective as the Kaneda and Synthes systems at limiting extension but was slightly less successful at limiting flexion. The Knodt system was effective at limiting extension but less effective in limiting flexion. The interfacet screws were effective at limiting flexion but less effective at limiting extension. Harrington rods to the sacral alae were the least effective system in both directions. Sublaminar wires did little to improve their performance.

Entities:  

Mesh:

Year:  1987        PMID: 3660083     DOI: 10.1097/00007632-198707000-00012

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  4 in total

1.  Biomechanical behaviour in vitro of the spine and lumbosacral junction.

Authors:  X Barthes; B Walter; R Zeller; J F Dubousset
Journal:  Surg Radiol Anat       Date:  1999       Impact factor: 1.246

2.  Lumbosacral fusion using the Boucher technique in combination with a posterolateral bone graft.

Authors:  M A El Masry; C J McAllen; C R Weatherley
Journal:  Eur Spine J       Date:  2003-06-11       Impact factor: 3.134

3.  Biomechanical evaluation of immediate stability with rectangular versus cylindrical interbody cages in stabilization of the lumbar spine.

Authors:  Dilip K Sengupta; S M H Mehdian; Robert C Mulholland; John K Webb; Donna D Ohnmeiss
Journal:  BMC Musculoskelet Disord       Date:  2002-10-03       Impact factor: 2.362

4.  Triggered Electromyography is a Useful Intraoperative Adjunct to Predict Postoperative Neurological Deficit Following Lumbar Pedicle Screw Instrumentation.

Authors:  Rajiv P Reddy; Robert Chang; Dominic V Coutinho; Justin W Meinert; Katherine M Anetakis; Donald J Crammond; Jeffrey R Balzer; Jeremy D Shaw; Joon Y Lee; Parthasarathy D Thirumala
Journal:  Global Spine J       Date:  2021-05-20
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.