Literature DB >> 3659384

Cervical cancer: intracavitary dose specification and prescription.

R A Potish1, B J Gerbi.   

Abstract

Dose and volume specifications for reporting intracavitary therapy were analyzed according to criteria recommended by the International Commission on Radiation Units and Measurements (ICRU). Ninety Fletcher-Suit radium applications were studied to examine the validity of the assumptions of the ICRU and the merit of their routine reporting. It was demonstrated that the reporting recommendations were inconsistent with clinical prescription systems and added little to dose specification. The distinction between dose specification and dose prescription was stressed.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3659384     DOI: 10.1148/radiology.165.2.3659384

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  1 in total

1.  Dosimetric evaluation of a newly designed low dose rate brachytherapy applicator for treatment of cervical cancer with extension into the lower vagina.

Authors:  Curtis Baker; Sharifeh A Dini; Mahesh Kudrimoti; Shahid B Awan; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2007-04-19       Impact factor: 2.102