Literature DB >> 3657491

31P magnetization transfer studies of creatine kinase kinetics in living rabbit brain.

H Degani1, J R Alger, R G Shulman, O A Petroff, J W Prichard.   

Abstract

The kinetics of the CK reaction in the living rabbit brain was studied by three 31P magnetization transfer methods: inversion recovery (IR), inversion transfer (IT), and steady-state saturation transfer (SSST). Longitudinal relaxation rates (tau -1) were determined from IR and IT experiments. The values were 0.88 +/- 0.08 s-1 for PCr and 2.45 +/- 0.39 s-1 for gamma-ATP. Analysis of the results of SSST experiments in which gamma-ATP was saturated yielded a forward rate constant kF of 0.53 +/- 0.07 s-1. Upon saturation of PCr no change in the gamma-ATP signal could be detected in SSST. An average reverse rate constant (kR +/- S.D.) of 0.52 +/- 0.04 s-1 was estimated by analyzing IT data from three experiments with selective inversion of gamma-ATP. The standard error of kR was 50%. The average [PCr]/[ATP] of 1.21 +/- 0.16 together with the values of kF and kR yielded a forward-to-reverse flux ratio of 1.23. Within our limits of accuracy this ratio was not significantly different from 1.0, thus suggesting that in the brain the forward and reverse CK fluxes are equal.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3657491     DOI: 10.1002/mrm.1910050102

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  13 in total

1.  Evidence for myocardial ATP compartmentation from NMR inversion transfer analysis of creatine kinase fluxes.

Authors:  F Joubert; B Gillet; J L Mazet; P Mateo; J Beloeil; J A Hoerter
Journal:  Biophys J       Date:  2000-07       Impact factor: 4.033

Review 2.  CK flux or direct ATP transfer: versatility of energy transfer pathways evidenced by NMR in the perfused heart.

Authors:  F Joubert; P Mateo; B Gillet; J C Beloeil; J L Mazet; J A Hoerter
Journal:  Mol Cell Biochem       Date:  2004 Jan-Feb       Impact factor: 3.396

3.  Abnormalities in High-Energy Phosphate Metabolism in First-Episode Bipolar Disorder Measured Using 31P-Magnetic Resonance Spectroscopy.

Authors:  Fei Du; Cagri Yuksel; Virginie-Anne Chouinard; Polly Huynh; Kyle Ryan; Bruce M Cohen; Dost Öngür
Journal:  Biol Psychiatry       Date:  2017-04-07       Impact factor: 13.382

4.  Dissociated expression of mitochondrial and cytosolic creatine kinases in the human brain: a new perspective on the role of creatine in brain energy metabolism.

Authors:  Matthew T J Lowe; Eric H Kim; Richard L M Faull; David L Christie; Henry J Waldvogel
Journal:  J Cereb Blood Flow Metab       Date:  2013-05-29       Impact factor: 6.200

Review 5.  What might be the impact on neurology of the analysis of brain metabolism by in vivo magnetic resonance spectroscopy?

Authors:  J Vion-Dury; D J Meyerhoff; P J Cozzone; M W Weiner
Journal:  J Neurol       Date:  1994-05       Impact factor: 4.849

6.  Tightly coupled brain activity and cerebral ATP metabolic rate.

Authors:  Fei Du; Xiao-Hong Zhu; Yi Zhang; Michael Friedman; Nanyin Zhang; Kâmil Ugurbil; Wei Chen
Journal:  Proc Natl Acad Sci U S A       Date:  2008-04-28       Impact factor: 11.205

7.  Activity of creatine kinase in a contracting mammalian muscle of uniform fiber type.

Authors:  E W McFarland; M J Kushmerick; T S Moerland
Journal:  Biophys J       Date:  1994-11       Impact factor: 4.033

Review 8.  Advanced In Vivo Heteronuclear MRS Approaches for Studying Brain Bioenergetics Driven by Mitochondria.

Authors:  Xiao-Hong Zhu; Fei Du; Nanyin Zhang; Yi Zhang; Hao Lei; Xiaoliang Zhang; Hongyan Qiao; Kamil Ugurbil; Wei Chen
Journal:  Methods Mol Biol       Date:  2009

9.  Functional energetic responses and individual variance of the human brain revealed by quantitative imaging of adenosine triphosphate production rates.

Authors:  Xiao-Hong Zhu; Byeong-Yeul Lee; Wei Chen
Journal:  J Cereb Blood Flow Metab       Date:  2018-04-10       Impact factor: 6.200

10.  Studying Enzymes by In Vivo C Magnetic Resonance Spectroscopy.

Authors:  Su Xu; Jun Shen
Journal:  Prog Nucl Magn Reson Spectrosc       Date:  2009-10-01       Impact factor: 9.795

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.