Literature DB >> 3653124

Fundamental differences between the standard 12-lead electrocardiograph and the modified (Mason-Likar) exercise lead system.

M Papouchado1, P R Walker, M A James, L M Clarke.   

Abstract

A comparison of the standard 12-lead electrocardiograph with the Mason-Likar lead system widely used for exercise stress testing shows that the two are not 'essentially identical' as was originally claimed. Placement of the limb electrodes onto the torso distorts the electrocardiograph causing a rightward shift of the mean QRS axis, a significant reduction in R-wave amplitude in leads I and aVL, and a significant increase in R-wave amplitude in leads II, III and aVF; the R-wave amplitude of the chest leads is also altered. The so-called 'inferior' leads on the exercise electrocardiography are probably modified anterior/inferior leads, since their R-wave amplitudes correlate closely with those of antero-lateral chest leads. The inferior surface of the heart is not represented in isolation on the exercise electrocardiograph, thus explaining the reported inability of the exercise test to predict the location of coronary artery disease and high incidence of false negative tests in patients with ischaemia limited to the inferior cardiac surface.

Entities:  

Mesh:

Year:  1987        PMID: 3653124     DOI: 10.1093/eurheartj/8.7.725

Source DB:  PubMed          Journal:  Eur Heart J        ISSN: 0195-668X            Impact factor:   29.983


  16 in total

1.  Modified electrode placement must be recorded when performing 12-lead electrocardiograms.

Authors:  N I Jowett; A M Turner; A Cole; P A Jones
Journal:  Postgrad Med J       Date:  2005-02       Impact factor: 2.401

Review 2.  Technical mistakes during the acquisition of the electrocardiogram.

Authors:  Javier García-Niebla; Pablo Llontop-García; Juan Ignacio Valle-Racero; Guillem Serra-Autonell; Velislav N Batchvarov; Antonio Bayés de Luna
Journal:  Ann Noninvasive Electrocardiol       Date:  2009-10       Impact factor: 1.468

3.  The Selvester QRS Score is more accurate than Q waves and fragmented QRS complexes using the Mason-Likar configuration in estimating infarct volume in patients with ischemic cardiomyopathy.

Authors:  Mary G Carey; Andrew J Luisi; Sunil Baldwa; Salah Al-Zaiti; Marc J Veneziano; Robert A deKemp; John M Canty; James A Fallavollita
Journal:  J Electrocardiol       Date:  2010-04-08       Impact factor: 1.438

4.  2017 ISHNE-HRS expert consensus statement on ambulatory ECG and external cardiac monitoring/telemetry.

Authors:  Jonathan S Steinberg; Niraj Varma; Iwona Cygankiewicz; Peter Aziz; Paweł Balsam; Adrian Baranchuk; Daniel J Cantillon; Polychronis Dilaveris; Sergio J Dubner; Nabil El-Sherif; Jaroslaw Krol; Malgorzata Kurpesa; Maria Teresa La Rovere; Suave S Lobodzinski; Emanuela T Locati; Suneet Mittal; Brian Olshansky; Ewa Piotrowicz; Leslie Saxon; Peter H Stone; Larisa Tereshchenko; Mintu P Turakhia; Gioia Turitto; Neil J Wimmer; Richard L Verrier; Wojciech Zareba; Ryszard Piotrowicz
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-05       Impact factor: 1.468

5.  Exercise-Induced Premature Ventricular Contractions Are Associated With Myocardial Ischemia Among Asymptomatic Adult Male Firefighters: Implications for Enhanced Risk Stratification.

Authors:  Dillon J Dzikowicz; Mary G Carey
Journal:  Biol Res Nurs       Date:  2020-04-28       Impact factor: 2.522

6.  Obesity and hypertension contribute to prolong QRS complex duration among middle-aged adults.

Authors:  Dillon J Dzikowicz; Mary G Carey
Journal:  Ann Noninvasive Electrocardiol       Date:  2019-05-29       Impact factor: 1.468

7.  Assessment of heart rate response to exercise and recovery during treadmill testing in arsenic-exposed workers.

Authors:  Ugur Nadir Karakulak; Meside Gunduzoz; Mehmet Ayturk; Mujgan Tek Ozturk; Engin Tutkun; Omer Hinc Yilmaz
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-03-01       Impact factor: 1.468

8.  The new universal definition of myocardial infarction criteria improve electrocardiographic diagnosis of acute coronary syndrome.

Authors:  Kirsten E Fleischmann; Jessica Zègre-Hemsey; Barbara J Drew
Journal:  J Electrocardiol       Date:  2011 Jan-Feb       Impact factor: 1.438

9.  Widened QRS-T Angle May Be a Measure of Poor Ventricular Stretch During Exercise Among On-duty Firefighters.

Authors:  Dillon J Dzikowicz; Mary G Carey
Journal:  J Cardiovasc Nurs       Date:  2019 May/Jun       Impact factor: 2.083

10.  A new electrode placement method for obtaining 12-lead ECGs.

Authors:  Gabriel M Khan
Journal:  Open Heart       Date:  2015-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.