Effect of compression pressure on forced expiratory flow in infants.

P N Le Souëf, D M Hughes, L I Landau.   

Abstract

The effect of the force of compression on expiratory flow was evaluated in 19 infants (2-13 mo of age) with respiratory illnesses of varying severity. An inflatable cuff was used to compress the chest and abdomen. Expiratory flow and volume, airway occlusion pressure, cuff pressure (Pc), and functional residual capacity were measured. Transmission of pressure from cuff to pleural space was assessed by a noninvasive occlusion technique. Close correlations (P less than 0.001) were found between Pc and the change in pleural pressure with cuff inflation (delta Ppl,c). Pressure transmission was found to vary between two cuffs of different design and between infants. Several forced expirations were then performed on each infant at various levels of delta Ppl,c. Infants with low maximal expiratory flows at low lung volumes required relatively gentle compression to achieve flow limitation and showed decreased flow for firmer compressions. Flow-volume curves in each infant tended to become more concave as delta Ppl,c increased. These findings underline the importance of knowledge of delta Ppl,c in interpreting expiratory flow-volume curves in infants.

Entities:  

Mesh:

Year:  1986        PMID: 3640761     DOI: 10.1152/jappl.1986.61.5.1639

Source DB:  PubMed          Journal:  J Appl Physiol (1985)        ISSN: 0161-7567


  9 in total

1.  Repeatability of lung function tests during methacholine challenge in wheezy infants.

Authors:  C Delacourt; M R Benoist; S Waernessyckle; P Rufin; J J Brouard; J de Blic; P Scheinmann
Journal:  Thorax       Date:  1998-11       Impact factor: 9.139

2.  Bronchial responsiveness and lung function in infants with lower respiratory tract illness over the first six months of life.

Authors:  J R Clarke; A Reese; M Silverman
Journal:  Arch Dis Child       Date:  1992-12       Impact factor: 3.791

Review 3.  Lung function testing in infancy.

Authors:  A D Milner
Journal:  Arch Dis Child       Date:  1990-05       Impact factor: 3.791

4.  Validity of forced expiratory flow volume loops in neonates.

Authors:  P N LeSouëf; L I Landau
Journal:  Arch Dis Child       Date:  1988-04       Impact factor: 3.791

5.  Early detection of lung function abnormalities in infants with cystic fibrosis.

Authors:  R Kraemer
Journal:  J R Soc Med       Date:  1989       Impact factor: 5.344

6.  Disturbance in respiratory mechanics in infants with bronchiolitis.

Authors:  J Seidenberg; I B Masters; I Hudson; A Olinsky; P D Phelan
Journal:  Thorax       Date:  1989-08       Impact factor: 9.139

7.  Dose-response relationships and time course of the response to systemic beta adrenoreceptor agonists in infants with bronchopulmonary disease.

Authors:  R Kraemer; P Birrer; M H Schöni
Journal:  Thorax       Date:  1988-10       Impact factor: 9.139

8.  Delivery of salbutamol by metered dose inhaler and valved spacer to wheezy infants: effect on bronchial responsiveness.

Authors:  J R Clarke; H Aston; M Silverman
Journal:  Arch Dis Child       Date:  1993-07       Impact factor: 3.791

Review 9.  Monitoring early inflammation in CF. Infant pulmonary function testing.

Authors:  Jack K Sharp
Journal:  Clin Rev Allergy Immunol       Date:  2002-08       Impact factor: 8.667

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.