Literature DB >> 3636817

An instrument to assess the dynamic characteristics of the circumvaginal musculature.

M C Dougherty, R Abrams, P L McKey.   

Abstract

This report describes an intravaginal balloon device (IVBD) and an improved method for measuring the dynamic characteristics of circumvaginal muscle (CVM) contractions. The IVBD measurement system may be used in research on women's health problems related to the pelvic floor musculature. The system is independent of examiner judgment and variability, and measurement conditions are carefully controlled. In an initial trial using the device with 20 volunteers, aged 22 to 58 years, the maximal pressure developed during strong CVM contractions was measured with the subjects supine. Subjects were asked to repeat the contraction while they contracted abdominal muscles. The length of time a submaximal contraction could be held was also measured. Test-retest reliability, determined by repeating each experiment, revealed significant correlations in maximal pressure attained, r = .85, p less than .03. A t test demonstrated no significant difference between the variables with and without the use of abdominal muscles, indicating the contraction of abdominal muscles did not affect intravaginal pressure when assessed with the IVBD. A weak correlation between length of time a submaximal contraction could be held and age of subject was found, r = -.44, p less than .06, but no pressure variable was correlated with age or parity, a possible effect of the small sample in this study.

Entities:  

Mesh:

Year:  1986        PMID: 3636817

Source DB:  PubMed          Journal:  Nurs Res        ISSN: 0029-6562            Impact factor:   2.381


  6 in total

1.  Test-retest reliability of an instrumented speculum for measuring vaginal closure force.

Authors:  J M Miller; J A Ashton-Miller; D Perruchini; J O L DeLancey
Journal:  Neurourol Urodyn       Date:  2007       Impact factor: 2.696

2.  Is cesarean section a real panacea to prevent pelvic organ disorders?

Authors:  Onder Koc; Bulent Duran; Safak Ozdemırcı; Yesim Bakar; Nuriye Ozengin
Journal:  Int Urogynecol J       Date:  2011-05-28       Impact factor: 2.894

3.  The effect of pregnancy and childbirth on pelvic floor muscle function.

Authors:  Ksena Elenskaia; Ranee Thakar; Abdul Hameed Sultan; Inka Scheer; Andrew Beggs
Journal:  Int Urogynecol J       Date:  2011-07-26       Impact factor: 2.894

Review 4.  Ethical and practice considerations for biofeedback therapists in the treatment of urinary incontinence.

Authors:  P Paul; J E Cassisi; P Larson
Journal:  Biofeedback Self Regul       Date:  1996-09

5.  Dynamic assessment of the vaginal high-pressure zone using high-definition manometery, 3-dimensional ultrasound, and magnetic resonance imaging of the pelvic floor muscles.

Authors:  Varuna Raizada; Valmik Bhargava; Sung-Ae Jung; Anna Karstens; Dolores Pretorius; Petr Krysl; Ravinder K Mittal
Journal:  Am J Obstet Gynecol       Date:  2010-05-11       Impact factor: 8.661

Review 6.  Mechanisms of pelvic floor muscle training for managing urinary incontinence in women: a scoping review.

Authors:  Ying Sheng; Janet S Carpenter; James A Ashton-Miller; Janis M Miller
Journal:  BMC Womens Health       Date:  2022-05-13       Impact factor: 2.742

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.