Stability of serum alanine aminotransferase activity.

K M Williams, A E Williams, L M Kline, R Y Dodd.   

Abstract

In this study the authors examine the effects of common storage and handling procedures on serum alanine aminotransferase (ALT) levels. Clotted blood samples from 14 subjects were centrifuged at 280 X g for 10 minutes. Serum was tested immediately for baseline ALT levels and aliquots were stored at 22, 4, -20, and -80 degrees C. Additional serums were stored on the clot at 22 and 4 degrees C. ALT quantitation was performed at intervals of 3, 6, 9, and 24 hours and on Days 2, 4, 6, and 8. Unseparated tubes were sampled both proximal and distal to the red cells to determine ALT leakage from red cells lysis. For all storage conditions, gradual loss of activity occurred over time. Mean activity loss in separated serum at 2 days was 6 percent at 4 degrees C and 20 percent at 22 degrees C. Mean loss in unseparated serum was 3 percent at 4 degrees C and 12 percent at 22 degrees C. Marked ALT loss averaging 46 percent by day 6 occurred with storage at -20 degrees C, whereas storage at -80 degrees C resulted in an 8 percent decrease for the same period. For storage of up to 1 week, it is recommended that serum be separated early and retained at 4 degrees C. Frozen samples should be kept at -80 degrees C. Storage of separated or unseparated blood for up to 24 hours at 22 or 4 degrees C, as commonly found in blood centers, will marginally adversely affect the accuracy of ALT determination.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3629675     DOI: 10.1046/j.1537-2995.1987.27587320539.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  6 in total

Review 1.  Gender and racial differences in nonalcoholic fatty liver disease.

Authors:  Jen-Jung Pan; Michael B Fallon
Journal:  World J Hepatol       Date:  2014-05-27

2.  Performance of an Optimized Paper-Based Test for Rapid Visual Measurement of Alanine Aminotransferase (ALT) in Fingerstick and Venipuncture Samples.

Authors:  Sidhartha Jain; Radha Rajasingham; Farzad Noubary; Erin Coonahan; Ryan Schoeplein; Rachel Baden; Michael Curry; Nezam Afdhal; Shailendra Kumar; Nira R Pollock
Journal:  PLoS One       Date:  2015-05-28       Impact factor: 3.240

3.  Expression, purification, and initial characterization of human alanine aminotransferase (ALT) isoenzyme 1 and 2 in High-five insect cells.

Authors:  Li Liu; Shao Zhong; Rongze Yang; Hong Hu; Daozhan Yu; Dalong Zhu; Zichun Hua; Alan R Shuldiner; Richard Goldstein; William J Reagan; Da-Wei Gong
Journal:  Protein Expr Purif       Date:  2008-04-26       Impact factor: 1.650

4.  Hospital-based surveillance for viral hemorrhagic fevers and hepatitides in Ghana.

Authors:  Joseph Humphrey Kofi Bonney; Mubarak Osei-Kwasi; Theophilus Korku Adiku; Jacob Samson Barnor; Robert Amesiya; Chrysantus Kubio; Lawson Ahadzie; Stephan Olschläger; Michaela Lelke; Beate Becker-Ziaja; Meike Pahlmann; Stephan Günther
Journal:  PLoS Negl Trop Dis       Date:  2013-09-19

5.  Trajectories of Metabolic Risk Factors and Biochemical Markers prior to the Onset of Cardiovascular Disease - The Doetinchem Cohort Study.

Authors:  Gerben Hulsegge; Annemieke M W Spijkerman; Yvonne T van der Schouw; Stephan J L Bakker; Ron T Gansevoort; Henriette A Smit; W M Monique Verschuren
Journal:  PLoS One       Date:  2016-05-20       Impact factor: 3.240

6.  Assays for Qualification and Quality Stratification of Clinical Biospecimens Used in Research: A Technical Report from the ISBER Biospecimen Science Working Group.

Authors:  Fay Betsou; Alexandre Bulla; Sang Yun Cho; Judith Clements; Rodrigo Chuaqui; Domenico Coppola; Yvonne De Souza; Annemieke De Wilde; William Grizzle; Fiorella Guadagni; Elaine Gunter; Stacey Heil; Verity Hodgkinson; Joseph Kessler; Michael Kiehntopf; Hee Sung Kim; Iren Koppandi; Katheryn Shea; Rajeev Singh; Marc Sobel; Stella Somiari; Demetri Spyropoulos; Mars Stone; Gunnel Tybring; Klara Valyi-Nagy; Gert Van den Eynden; Lalita Wadhwa
Journal:  Biopreserv Biobank       Date:  2016-04-05       Impact factor: 2.300

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.