Dynamic in vivo response characteristics of three oximeters: Hewlett-Packard 47201A, Biox III, and Nellcor N-100.

P West, C F George, M H Kryger.   

Abstract

Pulse oximeters (Biox III, Nellcor N-100) and a transmittance oximeter [Hewlett-Packard 47201A (HP)] were compared for SaO2 measurement and responsiveness during dynamic changes in arterial oxygen saturation and heart rate. Five sleep apnea syndrome patients were studied because they had large oscillations in SaO2 and heart rate in sleep. During sleep, each patient exhibited a series of rapid (18.0 +/- 8.3 s, mean +/- SD) oscillations in oxygen saturation (92.1 +/- 2.6% to 74.2 +/- 7.7%). Oxygen saturation measurements were sampled simultaneously from each oximeter by computer (at 2 Hz). Accuracy was assessed by comparing pulse and transmittance oxygen saturation measurements at the peak and trough of each apnea-related oscillation. Oximeter response was defined in terms of the "delay" or absolute time difference between the pulse oximeters and the transmittance oximeter for the determination of the peak and trough saturations. Linear regression analysis was used to establish accuracy and response relationships between pulse oximeter sensors (reusable ear, reusable digit, disposable digit, and disposable nasal sensors) and the transmittance oximeter sensor (reusable ear sensor). Pulse oximeter response delay was highly correlated with heart rate. Pulse oximeter SaO2 measurement and response characteristics varied considerably with sensor type (disposable, reusable) and sensor location (ear, nose, and digit). One must be aware of these differences in clinical and research application.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3629089     DOI: 10.1093/sleep/10.3.263

Source DB:  PubMed          Journal:  Sleep        ISSN: 0161-8105            Impact factor:   5.849


  4 in total

Review 1.  How much polysomnography is enough?

Authors:  D Kurtz
Journal:  Lung       Date:  1990       Impact factor: 2.584

2.  Prediction of oxygenation during sleep in patients with chronic obstructive lung disease.

Authors:  J L McKeon; K Murree-Allen; N A Saunders
Journal:  Thorax       Date:  1988-04       Impact factor: 9.139

3.  Pulse oximetry for the detection of obstructive sleep apnea syndrome: can the memory capacity of oxygen saturation influence their diagnostic accuracy?

Authors:  Carlos A Nigro; Eduardo Dibur; Edgardo Rhodius
Journal:  Sleep Disord       Date:  2011-10-19

Review 4.  The Various Oximetric Techniques Used for the Evaluation of Blood Oxygenation.

Authors:  Meir Nitzan; Itamar Nitzan; Yoel Arieli
Journal:  Sensors (Basel)       Date:  2020-08-27       Impact factor: 3.576