Literature DB >> 3627004

Gibbs artifact removal in magnetic resonance imaging.

D L Parker, G T Gullberg, P R Frederick.   

Abstract

Gibbs artifact in magnetic resonance imaging results when band-limited interpolation is used. This is typically done when there are more reconstructed pixels in the phase encoding direction of the image than corresponding phase encoding measurements. Such sampling is effectively an ideal (in a noise sense) low-pass filter which provides a maximal improvement in contrast resolution at the expense of a decrease in spatial resolution. In this paper we demonstrate that an alternate low-pass filter can be used to improve contrast resolution with a loss in spatial resolution and yet not result in Gibbs artifact. We show that the noise performance of this filter can be made to approach that of an ideal filter by properly specifying the number of samples averaged for each phase encoding index.

Mesh:

Year:  1987        PMID: 3627004     DOI: 10.1118/1.596032

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  10 in total

1.  On the dark rim artifact in dynamic contrast-enhanced MRI myocardial perfusion studies.

Authors:  E V R Di Bella; D L Parker; A J Sinusas
Journal:  Magn Reson Med       Date:  2005-11       Impact factor: 4.668

2.  Parallel acquisition for effective density weighted imaging: PLANED imaging.

Authors:  Oliver M Geier; Dietbert Hahn; Herbert Köstler
Journal:  MAGMA       Date:  2007-01-20       Impact factor: 2.310

3.  In vivo three-dimensional molecular imaging with Biosensor Imaging of Redundant Deviation in Shifts (BIRDS) at high spatiotemporal resolution.

Authors:  Daniel Coman; Robin A de Graaf; Douglas L Rothman; Fahmeed Hyder
Journal:  NMR Biomed       Date:  2013-07-24       Impact factor: 4.044

4.  Adenosine stress cardiovascular magnetic resonance with variable-density spiral pulse sequences accurately detects coronary artery disease: initial clinical evaluation.

Authors:  Michael Salerno; Angela Taylor; Yang Yang; Sujith Kuruvilla; Michael Ragosta; Craig H Meyer; Christopher M Kramer
Journal:  Circ Cardiovasc Imaging       Date:  2014-04-23       Impact factor: 7.792

5.  Non-spin-echo 3D transverse hadamard encoded proton spectroscopic imaging in the human brain.

Authors:  Ouri Cohen; Assaf Tal; Gadi Goelman; Oded Gonen
Journal:  Magn Reson Med       Date:  2012-08-24       Impact factor: 4.668

6.  Minimizing lipid signal bleed in brain (1) H chemical shift imaging by post-acquisition grid shifting.

Authors:  Yi Zhang; Jinyuan Zhou; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2014-08-28       Impact factor: 4.668

7.  In vivo free induction decay based 3D multivoxel longitudinal hadamard spectroscopic imaging in the human brain at 3 T.

Authors:  Assaf Tal; Gadi Goelman; Oded Gonen
Journal:  Magn Reson Med       Date:  2012-05-10       Impact factor: 4.668

8.  Density-weighted concentric rings k-space trajectory for 1 H magnetic resonance spectroscopic imaging at 7 T.

Authors:  Mark Chiew; Wenwen Jiang; Brian Burns; Peder Larson; Adam Steel; Peter Jezzard; M Albert Thomas; Uzay E Emir
Journal:  NMR Biomed       Date:  2017-10-18       Impact factor: 4.044

9.  Improved first-pass spiral myocardial perfusion imaging with variable density trajectories.

Authors:  Michael Salerno; Christopher Sica; Christopher M Kramer; Craig H Meyer
Journal:  Magn Reson Med       Date:  2012-12-27       Impact factor: 4.668

10.  Boosting BOLD fMRI by K-space density weighted echo planar imaging.

Authors:  Mario Zeller; Alexander Müller; Marcel Gutberlet; Thomas Nichols; Dietbert Hahn; Herbert Köstler; Andreas J Bartsch
Journal:  PLoS One       Date:  2013-09-10       Impact factor: 3.240

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.