Comparison of respiratory inductive plethysmography and thoracic impedance for apnea monitoring.

R T Brouillette, A S Morrow, D E Weese-Mayer, C E Hunt.   

Abstract

Thoracic impedance apnea monitors may fail to detect obstructive apnea, may falsely alarm when the infant is breathing, and may confuse cardiac artifact with respiratory impedance. Therefore, we compared the performance of a respiratory inductive plethysmograph and a thoracic impedance monitor with a reliable measure of airflow, either nasal CO2 or pneumotachograph, during 29 studies in 28 patients referred for sleep laboratory evaluation. Sleep time averaged 72 +/- 37 (SD) minutes. The inductance plethysmography and the impedance monitor detected 99.6% +/- 0.6% and 98.3% +/- 3.0% of breaths, respectively. However, in two studies, the impedance monitor detected many extra breaths, once because of cardiac-induced impedance changes and once because of partial airway obstruction-induced impedance changes. In 11 studies, cardiac artifact was sometimes misinterpreted as a breath by the impedance monitor. The impedance monitor, but not the inductance plethysmograph, missed breaths following sighs in 16 of 29 studies. Both monitors detected all 60 episodes of central apnea. The inductance plethysmography detected 35 of 38 episodes of obstructive apnea, but the impedance monitor identified only two such events. Apnea was detected falsely four times by the inductance plethysmograph and 14 times by the impedance monitor. These results suggests that a respiratory inductive plethysmograph would have significant advantages over impedance monitoring, including the ability to detect obstructive apnea, and freedom from cardiac artifact.

Entities:  

Mesh:

Year:  1987        PMID: 3625404     DOI: 10.1016/s0022-3476(87)80457-2

Source DB:  PubMed          Journal:  J Pediatr        ISSN: 0022-3476            Impact factor:   4.406


  10 in total

1.  Assessment of noninvasive acoustic respiration rate monitoring in patients admitted to an Emergency Department for drug or alcoholic poisoning.

Authors:  Youcef Guechi; Amélie Pichot; Denis Frasca; Fatima Rayeh-Pelardy; Jean-Yves Lardeur; Olivier Mimoz
Journal:  J Clin Monit Comput       Date:  2015-01-23       Impact factor: 2.502

2.  Polysomnography and home documented monitoring of cardiorespiratory pattern.

Authors:  H Daniëls; G Naulaers; F Deroost; H Devlieger
Journal:  Arch Dis Child       Date:  1999-11       Impact factor: 3.791

3.  Postoperative desaturation and bradypnea after general anesthesia in non-ICU patients: a retrospective evaluation.

Authors:  Masashi Ishikawa; Atsuhiro Sakamoto
Journal:  J Clin Monit Comput       Date:  2019-03-02       Impact factor: 2.502

4.  An automated sleep-analysis system operated through a standard hospital monitor.

Authors:  Offer Amir; Deganit Barak-Shinar; Yariv Amos; Mary MacDonald; Stephen Pittman; David P White
Journal:  J Clin Sleep Med       Date:  2010-02-15       Impact factor: 4.062

5.  Real-Time Measurements of Relative Tidal Volume and Stroke Volume Using Electrical Impedance Tomography with Spatial Filters: A Feasibility Study in a Swine Model Under Normal and Reduced Ventilation.

Authors:  Geuk Young Jang; Chi Ryang Chung; Ryoung Eun Ko; Jin Young Lee; Tong In Oh; Gee Young Suh; Yongmin Kim; Eung Je Woo
Journal:  Ann Biomed Eng       Date:  2022-08-12       Impact factor: 4.219

6.  Sleep disordered breathing analysis in a general population using standard pulse oximeter signals.

Authors:  Deganit Barak-Shinar; Yariv Amos; Richard K Bogan
Journal:  Sleep Breath       Date:  2013-02-06       Impact factor: 2.816

7.  Quantitative Analysis of Thoracoabdominal Asynchrony in Pediatric Polysomnography.

Authors:  Jason Z Bronstein; Li Xie; Thomas H Shaffer; Aaron Chidekel; Robert Heinle
Journal:  J Clin Sleep Med       Date:  2018-07-15       Impact factor: 4.062

8.  Linshom respiratory monitoring device: a novel temperature-based respiratory monitor.

Authors:  Jerrold Lerman; Doron Feldman; Ronen Feldman; John Moser; Leeshi Feldman; Madhankumar Sathyamoorthy; Kenneth Deitch; Uri Feldman
Journal:  Can J Anaesth       Date:  2016-07-13       Impact factor: 6.713

9.  Scoring Tools for the Analysis of Infant Respiratory Inductive Plethysmography Signals.

Authors:  Carlos Alejandro Robles-Rubio; Gianluca Bertolizio; Karen A Brown; Robert E Kearney
Journal:  PLoS One       Date:  2015-07-28       Impact factor: 3.240

10.  Analysis of the parameters of respiration patterns extracted from thermal image sequences.

Authors:  Jacek Rumiński
Journal:  Biocybern Biomed Eng       Date:  2016-08-20       Impact factor: 4.314

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.