Motion robust 4D-MRI sorting based on anatomic feature matching: A digital phantom simulation study.

Zi Yang1, Lei Ren1,2, Fang-Fang Yin1,2, Xiao Liang1, Jing Cai2,3.   

Abstract

Purpose: Motion artifacts induced by breathing variations are common in 4D-MRI images. This study aims to reduce the motion artifacts by developing a novel, robust 4D-MRI sorting method based on anatomic feature matching and applicable in both cine and sequential acquisition. Method: The proposed method uses the diaphragm as the anatomic feature to guide the sorting of 4D-MRI images. Initially, both abdominal 2D sagittal cine MRI images and axial MRI images were acquired. The sagittal cine MRI images were divided into 10 phases as ground truth. Next, the phase of each axial MRI image is determined by matching its diaphragm position in the intersection plane to the ground truth cine MRI. Then, those matched phases axial images were sorted into 10-phase bins which were identical to the ground truth cine images. Finally, 10-phase 4D-MRI were reconstructed from these sorted axial images. The accuracy of reconstructed 4D-MRI data was evaluated by comparing with the ground truth using the 4D extended Cardiac Torso (XCAT) digital phantom. The effects of breathing signal, including both regular (cosine function) and irregular (patient data) in both axial cine and sequential scanning modes, on reconstruction accuracy were investigated by calculating total relative error (TRE) of the 4D volumes, Volume-Percent-Difference (VPD) and Center-of-Mass-Shift (COMS) of the estimated tumor volume, compared with the ground truth XCAT images.
Results: In both scanning modes, reconstructed 4D-MRI images matched well with ground truth with minimal motion artifacts. The averaged TRE of the 4D volume, VPD and COMS of the EOE phase in both scanning modes are 0.32%/1.20%/±0.05 mm for regular breathing, and 1.13%/4.26%/±0.21 mm for patient irregular breathing.
Conclusion: The preliminary evaluation results illustrated the feasibility of the robust 4D-MRI sorting method based on anatomic feature matching. This method provides improved image quality with reduced motion artifacts for both cine and sequential scanning modes.

Entities:  

Keywords:  4D-MRI; Liver cancer; Motion artifacts; Simulation; XCAT

Year:  2020        PMID: 36247384      PMCID: PMC9559608          DOI: 10.1016/j.radmp.2020.01.003

Source DB:  PubMed          Journal:  Radiat Med Prot        ISSN: 2666-5557


  16 in total

Review 1.  4-dimensional computed tomography imaging and treatment planning.

Authors:  Paul Keall
Journal:  Semin Radiat Oncol       Date:  2004-01       Impact factor: 5.934

2.  4D MR imaging of respiratory organ motion and its variability.

Authors:  M von Siebenthal; G Székely; U Gamper; P Boesiger; A Lomax; Ph Cattin
Journal:  Phys Med Biol       Date:  2007-02-16       Impact factor: 3.609

3.  Four-dimensional magnetic resonance imaging for the determination of tumour movement and its evaluation using a dynamic porcine lung phantom.

Authors:  G Remmert; J Biederer; F Lohberger; M Fabel; G H Hartmann
Journal:  Phys Med Biol       Date:  2007-09-04       Impact factor: 3.609

4.  A Spatiotemporal-Constrained Sorting Method for Motion-Robust 4D-MRI: A Feasibility Study.

Authors:  Chunhao Wang; Ergys Subashi; Fang-Fang Yin; Zheng Chang; Jing Cai
Journal:  Int J Radiat Oncol Biol Phys       Date:  2018-10-12       Impact factor: 7.038

5.  Audiovisual biofeedback improves the correlation between internal/external surrogate motion and lung tumor motion.

Authors:  Danny Lee; Peter B Greer; Chiara Paganelli; Joanna Jane Ludbrook; Taeho Kim; Paul Keall
Journal:  Med Phys       Date:  2018-02-19       Impact factor: 4.071

6.  Four-dimensional MRI using three-dimensional radial sampling with respiratory self-gating to characterize temporal phase-resolved respiratory motion in the abdomen.

Authors:  Zixin Deng; Jianing Pang; Wensha Yang; Yong Yue; Behzad Sharif; Richard Tuli; Debiao Li; Benedick Fraass; Zhaoyang Fan
Journal:  Magn Reson Med       Date:  2015-05-14       Impact factor: 4.668

7.  Four dimensional magnetic resonance imaging with retrospective k-space reordering: a feasibility study.

Authors:  Yilin Liu; Fang-Fang Yin; Nan-kuei Chen; Mei-Lan Chu; Jing Cai
Journal:  Med Phys       Date:  2015-02       Impact factor: 4.071

8.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing.

Authors:  Daniel A Low; Michelle Nystrom; Eugene Kalinin; Parag Parikh; James F Dempsey; Jeffrey D Bradley; Sasa Mutic; Sasha H Wahab; Tareque Islam; Gary Christensen; David G Politte; Bruce R Whiting
Journal:  Med Phys       Date:  2003-06       Impact factor: 4.071

9.  4D-MRI analysis of lung tumor motion in patients with hemidiaphragmatic paralysis.

Authors:  Julien Dinkel; Christian Hintze; Ralf Tetzlaff; Peter E Huber; Klaus Herfarth; Juergen Debus; Hans U Kauczor; Christian Thieke
Journal:  Radiother Oncol       Date:  2009-04-24       Impact factor: 6.280

10.  T2-weighted four dimensional magnetic resonance imaging with result-driven phase sorting.

Authors:  Yilin Liu; Fang-Fang Yin; Brian G Czito; Mustafa R Bashir; Jing Cai
Journal:  Med Phys       Date:  2015-08       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.